Specifications
www.nordsonefd.com info@nordsonefd.com Sales and service of Nordson EFD dispensing systems are available worldwide.
System Assembly 17
LVLP
valve
Lubricant
filter
Control
solenoid
Plant air
Filter
regulator
Tank
reservoir
To press shutdown
safety circuit
Grey wire
MC800
controller
Lubricant
Nozzle air
Control air
Single valve
6 mm4 mm
6 mm
4 mm
Dual valve
Air manifolds
for Single/ Dual
Note:
If both manifolds are being used with the
same fluid supply, install a “T” fitting #7022210
(supplied) in the lubricant filter outlet port.
Replace filter element #7017347 every 6 months
or 1000 hours of operation.
Dispose of used oil filters in accordance with
local environmental regulations.
4. Cut the clear fluid hose from the tank to
the controller so the end of the hose com-
ing from the tank can be installed into the
“IN” port of the filter adapter.
5. Connect the fluid hose from the controller
to the “OUT” port on the filter adapter.
6. Lubricate the filter gasket and screw the
filter onto the adapter until the gasket
makes contact and then tighten an addi-
tional 3/4 turn.
7. Refer to page 18 to wire the press
Emergency Stop Circuit and to connect the
low level switch cable to the controller.