setscrew
on bottom of manifold
Caution: Turn the system pressure off and
confirm that tank pressure is at zero before
performing maintenance on the system.
To remove a block-off plug or flow control,
loosen the setscrew on the bottom of the fluid
manifold block and pull the block-off or flow
control out of the manifold.
Note: To loosen/release the block-off and/or
the flow control from the manifold, it may
help to rotate them clockwise while you pull.
This will help free the 0-ring seal. The flow
control needs to be fully closed before the
body will turn within the manifold.
To provide proper air distribution and control, a press air solenoid must be installed in-line with the
white hose going to the
Control Air Input from Solenoid Fitting.
14
System Assembly
Important:
When the press is stamping, the solenoid must be open
continuously to allow constant spray from the MicroCoat system. This can
be accomplished by wiring the solenoid into the press clutch/run circuit.
Step 2: Installation/Removal of Flow Control/
Block-off Plug from Manifold
Step 3: Set Up the Controller
Step 4: Connect the Press Air Solenoid
Continued on page 16
To install a new flow control, lubricate the 0-
rings on the flow control with your stamping
oil and push the flow control into the manifold
while turning clockwise until the flow control
slides into place. Continue turning until the
zero on the knob is lined up with the zero ref-
erence on the flow control manifold. Tighten
the manifold setscrew firmly.
1. Place the controller and tank reservoir
away from traffic areas and position the
tank to allow for convenient refilling.
2. Set the controller System Pressure to the
Off position and the mode switch to the
Auto/Run position.
3. Refer to the diagram on page 15 and con-
nect a five micron filter regulator to the
plant air supply. Using the black and white
8 mm hoses supplied with the controller,
connect to the color-coded Constant Air
Input (black, 8 mm) and Control Air Input
from Solenoid (white, 8 mm) fittings at the
back of the controller.