Specifications
www.nordsonefd.com info@nordsonefd.com Sales and service of Nordson EFD dispensing systems are available worldwide.
9
13
12
11
10
8
7
6
6. Low Pressure Switch
Registers low fluid pressure. Connects with low
level switch for press protection.
WARNING: Must be wired to the
press Emergency Stop Circuit to
prevent the press from operating
without lubricant pressure (refer
to page 18).
7. Tank Air
Air from this port pressurizes the lubricant
reservoir.
8. Nozzle Air
Air from this port is used to spray the lubricant.
9. Valve Control Air
Air from this port controls the opening and
closing of the spray valves.
10. Fluid Outlet
Pressurized lubricant flows from these ports to
the spray valves.
11. Constant Air Input
The main air supply to the system should be a
minimum of 4.14 bar (60 psi)
.
12. Fluid Inlet
Lubricant from the tank reservoir enters the
manifold through this port.
13. Control Air Input from Solenoid
Activates the system when the press begins
stamping.
Minimum 4.14 bar (60 psi)
required
.
MC800 Rear View
Controller Features 11