Specifications
www.nordsonefd.com info@nordsonefd.com Sales and service of Nordson EFD dispensing systems are available worldwide.
2
1
5
4
3
1. System Pressure Switch
Turns the system air supply On and Off.
2. Mode Switch
Use
Manual/Setup
position to prime and test
the valves without running the press.
In the
Auto/Run
position, the system will spray
lubricant when the press begins stamping.
Press air solenoid must be properly
installed to allow the MicroCoat System
to run in Auto/Run mode (refer to pages
14-16).
3. Tank Air Pressure
Regulates air pressure in the lubricant reservoir.
For most lubricants, 1.03 bar (15 psi) is a good
start.
Minimum setting is 0.83 bar (12 psi).
4. Nozzle Air
Regulates nozzle air pressure.
Average setting is 0.55 to 0.83 bar (8 to
12 psi).
Higher pressure provides finer spray.
5. Flow Controls
Provide independent flow control of the lubricant to
each spray valve. Each blue ring on the stem
coming out of the middle of the knob indicates one
complete revolution.
Turn counterclockwise to increase flow.
Controller Features
MC800 Front View
10 Controller Features