User Guide

0
5
VALVEMATE
7060RA
M
M
M
®
A NORDSON COMPANY
To pressurize
To exhaust
Installation
1. Mount valve using the 1/4-28
UNF tapped hole on the air
cylinder body.
2. Connect the fluid feed hose to
the reservoir outlet and the
valve-inlet port using the
appropriate fittings (supplied).
3. Connect the 4 mm diameter
air hoses from the valve to the
controller. The white goes to
the “A” port and the black
goes to the “B” port.
4. Connect the 6 mm diameter
air hoses from the motor to
the air preparation assembly.
The white connects to the
control valve. The black
connects to the motor speed
control fitting.
5. Fill the fluid reservoir. After
filling, secure the cover and
connect the reservoir air pres-
sure regulator to the air tee
using the flexible air line (sup-
plied). Attach the black male
quick-connect on the air line
to the reservoir regulator and
then attach the white quick-
connect to the air tee. To
pressurize the system, slide
the shut-off valve on the air
line toward the fluid reservoir.
6. Set the reservoir pressure reg-
ulator according to fluid vis-
cosity, to low for thin fluids 1
to 3 psi (0.07 to 0.2 bar) and
higher for thick fluids.
7. Set the needle stroke control
at one turn open. This is a
starting point. Final setting will
be determined by the desired
flow rate.
Prior to installing this valve,
please read the associated
reservoir and valve controller
operating instructions to
become familiar with the opera-
tion of all components of the
dispensing system.
Output A
Output B
3
5
1
7
2
6
Air Preparation Assembly: See pages 6 – 7,
ValveMate 7060RA Controller Operating Manual.