User Guide

How the Valve Operates
ValveMate Concept
The ValveMate 7000 provides easy
adjustment of valve output for maximum
end-user convenience and efficiency.
Valve open-time is the primary control of
deposit. The 7000 puts push-button
adjustment of valve open-time where it
needs to be – at the valve.
Deposit size can be programmed by
pressing the PROGRAM button in the
SETUP mode. This affords an easy start-
ing point for selecting deposit size.
Note: The EFD Ultra TT 325 and 525
XYZ automated dispensing systems have
integrated ValveMate controllers for oper-
ating all EFD dispense valves.
POWER
RUN
SETUP
CYCLE
STOP
Test
Clear
Purge
Run
Setup Program
Fast Slow
Time Set
Steady
Pressure
Time
Fast Slow
Time Set
®
A NORDSON COMPANY
VALVEMATE
7000
Function Indicators
Emergency Stop
Control Pad
set time
timer bypass
display pressure (psi, bar)
TEACH program
test cycle
purge
reset
air input
power input
(voltage selector)
air output to valve
I/O connector with alarm
output (<60 psi)
connector for
optional foot pedal
Rear Panel
Pressure/Time Toggle
open closed
Input air pressure at 70 psi (4.8 bar) retracts
the piston and needle from the needle seat
in the dispensing tip
, permitting fluid flow
through the dispensing tip
. Once the
cycle is complete, air pressure is exhausted,
causing the piston spring
to return the
needle back to its position in the dispensing
tip, stopping fluid flow. When the dispensing
tip is removed, the needle seats into a sec-
ondary Teflon
®
seat
, stopping fluid flow
during tip replacement.
The amount of fluid dispensed
will depend on the time the valve
is open, fluid reservoir pressure,
dispensing tip size, needle stroke
and fluid viscosity.