User Guide
Shot Count/Deposit Volume (F3)
In PROGRAMMED DISPENSE mode, pressing the F3 button lets you toggle between Shot Count
and Deposit Volume.
• Shot Count displays and tracks the number of deposit cycles. You can reset the Shot Count
display to 0 by pressing the F4 button.
• Deposit Volume displays the current volume programmed in cc’s.
In MANUAL mode, the F3 button is not active.
Other F3 commands:
• From the Retract to Home screen, F3 allows you to select the Yes option.
• After you press the Barrel Select button, F3 allows you to set the Dispense Rate.
• From the Modify screen, F3 allows you to adjust the syringe barrel specification for diameter.
(See MODIFY, page 17.)
F4 Button
In both PROGRAMMED DISPENSE and MANUAL mode, the F4 button is not active until you are in
the screens noted below.
• From the Shot Count screen (F3), the F4 button allows you to reset the Shot Count to 0.
• From the Retract to Home screen (F1), F4 allows you to select the No option.
• From the Modify screen, F4 allows you to adjust the syringe barrel specifications for stroke.
(See MODIFY, page 17.)
Deposit Volume/Forward
In PROGRAMMED DISPENSE mode, press the Forward button to activate the Deposit Volume
screen. Use the (+) or (-) buttons to change the deposit volume as needed.
Deposit volume, measured in cc’s, is automatically linked to Forward steps in the Ultra 2800 stepper
motor. When you increase the cc setting, it automatically increases the number of Forward steps.
The maximum number of Forward steps is 65,534.
Deposit Volume is displayed when you press the F3/Shot Volume button.
In MANUAL mode, pressing and holding the Forward button will extend the plunger from the cable
assembly.
Features &
Controls
11