Switching from simple double code mode to parallel mode: Changing from double code to first code
During deletion, the first partial code is applied as the new first code.
Pressing the key combination P and 0 deletes all programmed functions (opening delay, ready-toopen
time).
Step Display
1. Open the lock with a valid double code (see page 31).
2. Press ON.
3. Press P.
4. Enter the valid double code again.
5. Press P. 1 x
6. Press 0. 1 x
⇒ 2. Par-
tial code
deleted
Closing
See page 30.
Opening delay and ready-to-open time functions
The opening delay is the time at the end of which it will be possible to open the lock. The ready-to-open time
is the time during which the lock can be opened once time opening delay has elapsed. An opening delay and
a ready-to-open time can be assigned to every valid code.
Enabling/Changing of the opening delay/ ready-to-open time
Step Display
1. Open the lock with a valid code.
2. Press ON.
3. Press P.
4. Enter the valid code again.
5. Press P.
6.
Press 1 when entering opening delay /ready-to-open time for:
- First code in parallel mode
- First code in delegated double code mode
- Double code in simple double code mode
Press 2 when entering opening delay /ready-to-open time for:
- Second code in parallel mode
- Double code in delegated double code mode
7. Entry of a two-figure opening delay (01-99 minutes) and
a single-figure ready-to-open time (1-9 minutes)
Example: 092 for 9 minutes opening delay and 2 minutes ready-to-open time
1 x
8.
Test the new opening delay and ready-to-open time just programmed by closing and
opening the lock again.