Technical data
Rittal Modular Safe LMS 9.3 Operation and functionality
We reserve the right to make technical changes Version 2.2
Operator Manual Page 33
Function “Simplified double code mode”
Activation of simple double code mode by the owner of the first code
This action deletes the first code and replaces it with a double code. The lock can now only be opened with
the first and second partial codes (four-eye principle).
Step Display
1. Open the lock with a valid 6-digit first code (see page 28).
2.
Press ON
.
3.
Press P
.
4. Enter the valid 6-digit Doppelcode again.
5.
Press P
.
6.
Press 7
.
7. Enter new 6-digit first partial code.
/ 2 x
8. Enter new 6-digit first partial code again.
1 x
9. Enter new 6-digit second partial code.
10. Enter new 6-digit second partial code again.
1x
11. Test the new double code just programmed by closing and opening the lock again.
In case the first or second partial codes have been incorrectly confirmed, the signal is given three times.
Repeat the procedure starting at step 2.
The order of the partial codes and their repeated confirmation has to be observed.
Opening with double code by the owner of the double code
Step Display
1. Press ON.
2. Enter the valid 6-digit first partial code.
1 x
3. Enter the valid 6-digit second partial code.
1 x
4. Turn the knob within 4 seconds clockwise until you can turn it no further.
The order of the partial codes has to be observed. For opening the lock, the first and then the second partial
code has to be entered.