Technical data
Rittal Modular Safe LMS 9.3 Operation and functionality
We reserve the right to make technical changes Version 2.2
Operator Manual Page 32
Changing the double code by the owner of the double code
Step Display
1. Open the lock with a valid double code (see page 31).
2.
Press ON
.
3.
Press P
.
4. Enter the valid double code again.
5. Enter the new 6-digit first partial code.
/2 x
6. Enter the new 6-digit first partial code again.
1x
7. Enter the new 6-digit second partial code.
8. Enter the new 6-digit second partial code again.
1x
9. Test the new double code just programmed by closing and opening the lock again.
If the first and second partial code have been incorrectly confirmed, the signal is given three times.
Repeat the procedure starting at step 2.
The order of the partial codes and their repeated confirmation has to be observed.
Deleting the double code by the owner of the first code
Step Display
1. Open the lock with a valid 6-digit first code (see page 31).
2.
Press ON
.
3.
Press P
.
4. Enter the valid 6-digit first code again.
5.
Press P
.
6.
Press 0
.
1x
⇒
Double-
code
deleted
All functions programmed can be deleted by pressing the P and 0 keys at the same time (second code,
double code, opening delay, ready-to-open time).
Closing
See page 30.