Technical data
Rittal Modular Safe LMS 9.3 Operation and functionality
We reserve the right to make technical changes Version 2.2
Operator Manual Page 31
Opening
Opening with first code by the owner of the first code
Step Display
1.
Press ON
.
2. Enter the valid 6-digit first code. 1 x
3. Turn the knob within 4 seconds clockwise until you can turn it no further.
In case the lock was last opened with the first code, the signal
is given three times.
Opening with double code by the owner of the double code
Step Display
1.
Press ON
.
2. Enter the valid 6-digit first. partial code. 1 x
3. Enter the valid 6-digit second partial code. 1 x
4. Turn the knob within 4 seconds clockwise until you can turn it no further.
In case the lock was last opened with the first code, the signal
is given three times.
The order of the partial codes has to be observed. For opening the lock muss at first the first code has to be
entered and then the second.
Opening after three or more incorrect code inputs ⇒ Disable period
If you attempt to enter a code after entering 3 incorrect codes, the lock is disabled for one minute. The dis-
able period is increased to 2, 4, 8, or a maximum of 16 minutes each time another incorrect code is input.
During the disabled period the red LED is flashing each second and further entering of the code is impossi-
ble. The disable period can be overridden using the revision key (see page 37).
Step Display
1. Once the lock is enabled again, you can press ON at any time.
2. Enter a valid code. 1 x
Information: Invalid code has been entered at an ealier opening test.
3 x
3. Turn the knob within 4 seconds clockwise until you can turn it no further.
Changing the first code by the owner of the first code
Step Display
1. Open the lock with a valid 6-digit first code (see page 31).
2.
Press ON
.
3.
Press P
.
4. Enter the valid 6-digit first code.
5. Enter the new 6-digit first code.
/2 x
6. Enter the new 6-digit first code again. 1 x
7. Test the new first code just programmed by opening the lock again with the door open.
If the new first code in 6) is incorrectly confirmed, the signal
is given three times.
Repeat the procedure starting at step 2.