Technical data
Rittal Modular Safe LMS 9.3 Operation and functionality
We reserve the right to make technical changes Version 2.2
Operator Manual Page 26
Signals and their meaning
Symbol Signal Meaning
1 x Green LED flashes once Valid 6-digit code entered
Green LED remains lit up Lock is ready for programming
3 x
Red LED flashes 3 times Invalid code entered
or
entry suspended by pressing P
button
10 x
Red LED fl ashes 10 times after
ON button pressed
Insufficient voltage
1, 2, 4, 8 or 16 minutes
Red LED flashes every second for
1, 2, 4, 8 or 16 minutes after ON
button pressed
Lock is in blocked status
Red LED flashes every 5 seconds Lock is in time delay status
3 x
Red and green LED flash alter-
nately 3 times
Lock was last opened with an-
other code
/
Red and green LED flash accom-
panied by an acoustic signal
cover plate removed for key
opening
/
Green LED flashes every 5 sec-
onds accompanied by an acoustic
signal
Lock is in opening window status
1 x
Acoustic signal sounds once End of opening window period
2 x
Acoustic signal sounds 2 times
During programming new 6-digit
code entered
3 x
Acoustic signal sounds 3 times
During programming invalid 6-
digit code entered