Rittal Modular Safe Extend (LMS 9.3) Operating manual EN V.2.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes Contents Version 2.2 1 Introduction ......................................................................................................... 4 1.1 Preliminary remarks ......................................................................................................................... 4 1.2 Safety instructions for the protection of persons.............................................................................. 5 1.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes Contents Version 2.2 5 Maintenance ...................................................................................................... 49 5.1 Maintenance contract..................................................................................................................... 49 5.2 Manintenance of the Safety cell..................................................................................................... 49 5.
Rittal Modular Safe LMS 9.3 Introduction We reserve the right to make technical changes 1 Introduction 1.1 Preliminary remarks Version 2.2 This operating manual is a part of the scope of delivery. Keep it and store it within easy reach near but never inside the Modular Safe LMS 9.3. The manufacturer reserves the right to make changes, in comparison with the technical data and illustrations provided in this operating manual, which are due to technical developments.
Rittal Modular Safe LMS 9.3 Introduction We reserve the right to make technical changes 1.2 Version 2.2 Safety instructions for the protection of persons DANGER Electric shock, electrocution Improperly performed work on the electrical equipment of the Modular Safe can result in serious injury or death.
Rittal Modular Safe LMS 9.3 Introduction We reserve the right to make technical changes Version 2.2 WARNING Risk of people getting locked in There is a risk of injury if people get locked in the not yet fully equipped safe. Before locking the not yet fully equipped Modular Safe, make sure that there are no more people inside. 1.
Rittal Modular Safe LMS 9.3 Introduction We reserve the right to make technical changes Version 2.2 NOTICE Always keep the keys to open the safety doors in a safe place that is inaccessible to unauthorized persons. Never keep the keys in the Modular Safe. NOTICE After installing the air conditioning unit, wait at least 2 hours before putting the equipment into operation. Start-up must only be done by duly authorized personnel.
Rittal Modular Safe LMS 9.3 Introduction We reserve the right to make technical changes Version 2.2 NOTICE Do not have duplicate keys made by a locksmith after you put the safe into operation. If you need additional keys, please contact the manufacturer’s Service Dept.. If any keys are lost, the lock must be exchanged without delay. 1.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes 2 Description of product 2.1 Description of purpose Description of product Version 2.2 The Rittal Modular Safe LMS 9.3 is a modular extendable mini data centre. The Modular Safe offers the highest level of physical security and efficient protection against fire, water and unauthorised access.
Rittal Modular Safe LMS 9.3 Description of product We reserve the right to make technical changes 2.2 Version 2.2 Description of product The Rittal Modular Safe LMS 9.3 consists of modular elements which are combined by means of a positive interlock arrangement. The Modular Safe can be installed whilst system is in operation and hardware components are housed within it.
Rittal Modular Safe LMS 9.3 Description of product We reserve the right to make technical changes 2.3 Version 2.2 Technical data Rittal Modular Safe LMS 9.3 – 47 HU, Inner depth 1020 mm Weight Modular Safe [kg] approx.
Rittal Modular Safe LMS 9.3 Description of product We reserve the right to make technical changes Version 2.2 2.4 Dimensional drawings 2.4.1 Single Modular Safe LMS 9.3 with two single doors Rittal Modular Safe LMS 9.
Rittal Modular Safe LMS 9.3 Description of product We reserve the right to make technical changes 2.4.2 Version 2.2 Single Modular Safe LMS 9.3 with one single and one double wing door Rittal Modular Safe LMS 9.
Rittal Modular Safe LMS 9.3 Description of product We reserve the right to make technical changes 2.5 Version 2.2 Cable ducts HINWEIS Expansions in the already installed cable bulkhead must only be done by duly authorized service personnel, otherwise all warranty claims will be rendered null and void! Inform the manufacturer if additional lines or cables are to be inserted into a cable bulkhead. 2.5.
Rittal Modular Safe LMS 9.3 Description of product We reserve the right to make technical changes 2.6 Version 2.2 Air-conditioning Temperature peaks, heat pockets in the Modular Safe or conductive dusts increase the risk of outage and reduce the service life of modern electronic components. The safe must be air-conditioned in order to provide a suitable atmospheric environment for the hardware components housed within it.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes Description of product Version 2.2 Outdoor solution In the outdoor solution, the vaporiser section of the air conditioning unit is identical to the compact solution positioned inside the modular safe. The weatherproof condensator together with the compressor are yet designed for the outside installation. Both circuits are connected together on site using coolant lines and the corresponding control cables.
Rittal Modular Safe LMS 9.3 Description of product We reserve the right to make technical changes Version 2.2 NOTICE The closed refrigeration circulation system contains coolant and oils. If these substances, or the air conditioning unit as a whole are exchanged, the waste materials must be disposed of in the proper manner for environmental protection purposes. This can be done by the equipment manufacturer.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes 2.6.2 Description of product Version 2.2 Liquid Cooling Package – LCP The LCP is a temperature-neutral cooling concept with a maximum refrigeration capacity of up to 20 kW. The LCP operates with cold water meaning that it requires a connection to the cold-water system provided by the customer or to a return cooler for generating cooling energy. This system is optimally suited for cooling hot spots.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes 3 Location surroundings 3.1 Static requirements Location surroundings Version 2.2 The floor at site where the Modular Safe LMS 9.3 is to be placed must be levelled and have an even surface. The floor must meet the determined working load in accordance with DIN 1045 (for instance reinforced concrete or ribbed stab floor). Definition of terms Working load: The weight of the Modular Safe LMS 9.
Rittal Modular Safe LMS 9.3 Location surroundings We reserve the right to make technical changes Version 2.2 If the floor construction does not correspond to DIN 1055, then a static calculation must be made before the Modular Safe LMS 9.3 is assembled, so as to ascertain whether the safe may be erected at the chosen site. If the floor construction does correspond to DIN 1045, then the Modular Safe LMS 9.
Rittal Modular Safe LMS 9.3 Location surroundings We reserve the right to make technical changes Version 2.2 Linkage of several Modular Safes A number of Modular Safes can be combined into one larger Modular Safe. This is known as linking or patching of Modular Safes. In one such case, the side elements of the Modular Safes, which are facing one another, are removed, thus creating a larger volume.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes 4 Operation and functionality 4.1 Handling of doors Version 2.2 When opening and closing doors of the Modular Safe, please observe the following instructions: WARNING Risk of getting jammed Injury can occur when opening and closing the safety doors. When opening and closing the doors, make sure that you do not get caught between the door and the frame. Keep a safe distance away.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 NOTICE Caution: Risk of the safe tipping over when the doors are opened 180° when the housing is empty! 4.1.1 Mechanical key lock NOTICE 2 keys are standardly supplied. All keys must be kept in a safe place that is inaccessible to unauthorized persons. If a key is lost, the lock must be exchanged! Keep the keys as clean as possible. The lock must not be oiled or greased.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 NOTICE Do not have duplicate keys made by a locksmith after you put the safe into operation. If you need additional keys, please contact the manufacturer’s Service Dept.. If any keys are lost, the lock must be exchanged without delay. 4.1.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Important safety information: NOTICE Programming operations can only be performed when the lock and safety door are open!! Each key input detected by the lock and found to be correct is acknowledged with an audible signal. These signals are not described in the following section. You have a maximum of 20 seconds to input each keystroke.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Operational modes The lock can be opened with a single code (primary code), with two codes (primary or secondary code), or with a dual code (1st and 2nd partial codes). Only the holder of the overriding primary code is able to release the secondary code and the dual code.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Function of the lock NOTICE Only perform programming operations when the lock and safe are open. Function “Parallel mode” Opening with the firstcode or secondcode Step Display 1. Press the ON key. 2. Enter a valid 6-digit first- or second code. 3. Turn the knob clockwise within four seconds until you can turn it no further.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Changing the first code by the owner of the first code Step Display 1. Open the lock with a valid 6-digit first code (see page 28). 2. Press ON. 3. Press P. 4. Enter the valid 6-digit first code. 5. Enter the new 6-digit first code. /2x 6. Enter the new 6-digit first code again. 1x 7. Test the new first code just programmed by closing and opening the lock again.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Deleting the second code by the owner of the first code Step 1. Open the lock with a valid 6-digit first code (see page 28). 2. Press ON. 3. Press P. 4. Enter the valid 6-digit first code. 5. Press P. 6. Press 0. Display 1x All functions programmed can be deleted by pressing the P and 0 keys at the same time.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Opening Opening with first code by the owner of the first code Step Display 1. Press ON. 2. Enter the valid 6-digit first code. 3. Turn the knob within 4 seconds clockwise until you can turn it no further. 1x In case the lock was last opened with the first code, the signal is given three times. Opening with double code by the owner of the double code Step Display 1. Press ON.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Changing the double code by the owner of the double code Step Display 1. Open the lock with a valid double code (see page 31). 2. Press ON. 3. Press P. 4. Enter the valid double code again. 5. Enter the new 6-digit first partial code. /2 x 6. Enter the new 6-digit first partial code again. 1x 7. Enter the new 6-digit second partial code. 8.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Function “Simplified double code mode” Activation of simple double code mode by the owner of the first code This action deletes the first code and replaces it with a double code. The lock can now only be opened with the first and second partial codes (four-eye principle). Step Display 1. Open the lock with a valid 6-digit first code (see page 28). 2. Press ON. 3. Press P. 4.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Opening after three or more incorrect code inputs ⇒ Blocking period If you attempt to enter a code after entering 3 incorrect codes, the lock is blocked for one minute. The block period is increased to 2, 4, 8, or a maximum of 16 minutes each time another incorrect code is input. During the blocked period the red LED is blinking each second and further entering of the code is impossible.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Switching from simple double code mode to parallel mode: Changing from double code to first code During deletion, the first partial code is applied as the new first code. Pressing the key combination P and 0 deletes all programmed functions (opening delay, ready-toopen time). Step Display 1. Open the lock with a valid double code (see page 31). 2. Press ON. 3. Press P. 4.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Opening when opening delay/ ready-to-open time is programmed Step 1. Press ON. 2. Enter a valid code. Display 1x Automatic beginning of the opening delay: visual signal every 5 seconds. After expiration of the opening delay: acoustic signal. Automatic beginning of the ready-to-open time: visual signal every 5 seconds. 3. Enter the valid code during the ready-to-open time again. 4.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes Operation and functionality Version 2.2 Power supply Power is supplied to the lock via a 9 V block battery (exception: power supply via alarm system). We recommend the use of an alkaline/manganese battery with reduced heavy metal content. When replacing batteries, please ensure environmentally-friendly disposal by using recycling/collection boxes. Never throw empty batteries into fire, water or domestic rubbish.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Opening Step Display 1. Push the tool into the right-hand hole until the catch opens. 2. Hold the tool in place whilst carefully lifting the cover. 3. Repeat the procedure with the left-hand hole. / 4. Now carefully remove the cover. / 5. Remove the bar handle and input shaft (square). 6. Replace cover (without bar handle) and snap into place. 7.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Short instructions on the revision opening To cut it: 4.1.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 4.2 Operating of the air-conditioning system 4.2.1 Climasplit compact unit Taking into service and standard operations After having created an electrical connection, the inner ventilator starts up and circulates the air inside the Modular Safe. This leads to an even temperature throughout the Modular Safe.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes 4.2.4 Version 2.2 Operating of the Comfort controller You can operate the cooling unit with the Comfort controller that is installed on the service door of the Modular Safe (not by the outdoor unit with inverter technology and not by the Liquid Cooling Package). NOTICE The set temperature of the basic controller has been set to 25 °C in the factory.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 NOTICE Note about the switching hysteresis: At a low hysteresis and thus short switching cycles, there is a danger that the cooling may be inadequate or only partial cooling occurring in some sections of the cabinet. NOTICE Note about the set temperature: The set temperature of the comfort controller has been set to 25 °C in the factory.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Variable parameters Progr. level Display screen Parameter Min. value Max. value Factory setting Description 1 St Setting for enclosure internal temperature Ti 20 55 35 The nominal value of the internal enclosure temperature is preset at the factory to 35°C and may be altered within a range of 20 – 55°C.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes Operation and functionality Version 2.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Defining system messages for evaluation System messages are shown on the display of the Comfort controller via the displays A1 to A20 and E0. A more detailed explanation of the system messages may be found in section “Evaluating system messages” on page 47. See also diagram on page 45. Progr. level Display screen Min. value Max.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.2 Evaluating system messages on the Comfort controller Display screen System message Possible cause Measures to rectify the fault A01 Enclosure open door Door open or door limit switch incorrectly positioned Close door, position door limit switch correctly, check connection if necessary A02 Enclosure interior temperature too high Cooling capacity too low/unit underdimensioned.
Rittal Modular Safe LMS 9.3 Operation and functionality We reserve the right to make technical changes Version 2.
Rittal Modular Safe LMS 9.3 Maintenance We reserve the right to make technical changes 5 Maintenance 5.1 Maintenance contract Version 2.2 We recommend, that a maintenance contract is concluded for an annual inspection. This safety inspection guarantees the full functionality of the Modular Safe LMS 9.3.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes Maintenance Version 2.2 Condensation drainage Condensate water must drain without interference. In case of condensation drainage over a large distance, it should be taken care that the hose does not bend sharply and that drainage is checked trouble-free to avoid backwatering and overflowing of condensate water. 5.3.
Rittal Modular Safe LMS 9.3 We reserve the right to make technical changes 6 Accessories Version 2.2 Accessories The following accessories are not part of the basic equipment and must thus be ordered separately if desired. 6.1 19“- Mounting rack A 19" rack is available as an accessory for installing system components in the Modular Safe LMS 9.3. Depending on the requirements, various shelves and intermediate racks can be inserted.
Rittal Modular Safe LMS 9.3 Accessories We reserve the right to make technical changes 6.2 Version 2.2 CMC-TC Computer Control Top Concept Description: The CMC is an intelligent monitor of the Modular Safes LMS 9.3 with a 10 Base T Ethernet connection. Emphasis was placed in the scope of functionality of the L-ISC package on the documentation and the monitoring of the physical parameters of the Modular Safe LMS 9.3. These functions are managed and controlled using different programs.
Rittal Modular Safe LMS 9.3 Accessories We reserve the right to make technical changes 6.3 Version 2.2 Early fire detection – EFD Plus The EFD Plus is an early fire detection system, which already detects and reports fires when their still in the pyrolysis phase. Method of functioning: Inside the EFD Plus housing, a fan creates a vacuum by which air from the safe is continuously taken in through a system of piping and directed to the two smoke detectors.
Rittal Modular Safe LMS 9.3 Accessories We reserve the right to make technical changes 6.5 Version 2.2 DET-AC Plus Slave fire alarm and extinguishing unit The DET-AC Plus Slave system is used when several security safes need extinguishing. The slave system always works in conjunction with the DET-AC Plus Master system (which already contains the extinguishing agent for three square metres) or with the EFD Plus system (just detection, no stored extinguishing agent).
Rittal Modular Safe LMS 9.3 Accessories We reserve the right to make technical changes 6.7 Version 2.2 Power System Module – PSM The greatly increasing demands on power by modern IT structures require optimised solutions for distributing power in racks and server safes. The PSM rail delivers an intelligent power-distribution system and reduces cabling and assembly work. The modular system offers a basic system in the shape of a vertical carrier rail with three-phase feed.
Schaltschrank-Systeme Industrial Enclosures Coffrets et armoires électriques Kastsystemen Apparatskåpssystem Armadi per quadri di comando Sistemas de armarios Stromverteilung Power Distribution Distribution de courant Stroomverdeling Strömfördelning Distribuzione di corrente Distribución de corriente Elektronik-Aufbau-Systeme Electronic Packaging Electronique Electronic Packaging Systems Electronic Packaging Contenitori per elettronica Sistemas para la electrónica System-Klimatisierung System Climate Con