5.5 Laying the cable around obstacles
When laying the cable around obstacles, maintain the
distances shown in the illustration.
min. 30 cm
min. 30 cm
When the distance is at least 30 cm, the robot lawnmower
interprets the distance as a path and moves around the
obstacle.
Note!
If there is a distance of 0 cm between the cables, it is
possible for the cable to be driven over.
min. 30 cm
0 cm
5.6 Connecting the boundary cable to the
base station
1 2
Remove the insulation from the boundary cable (2) after
laying the cable and connect to the spring terminals (1).
5.7 Connecting the low-voltage cables to the
transformer
2
1
3
4
Strip 10 mm of insulation o the low-voltage cables (3) and
(4).
Unscrew the screws with a screwdriver (2) and connect the
low-voltage cables (3) and (4) to the transformer (1).
The cables can be connected to either terminal, there is no
need to observe a particular polarity.
Insert the mains plug of the transformer into the mains
socket.