Operation Manual

30EN
PROBLEM LIKELY CAUSE SOLUTION
1. When the key is
turned to «RUN»,
the
indicator light or
the control panel
remain switched o
The safety device of the electronic
circuit board has cut in due to:
badly connected battery
battery terminals crossed
completely at battery
fuse blown
electronic circuit board wet
Turn the key to «STOP» and look
for the cause of the problem:
check connections (
3.4)
check connections (
3.4)
recharge the battery (
6.2.3)
replace the fuse (10 A) (
6.3.5)
dry using tepid air
2. With the key on
«START» the light
ashes and the
starter motor does
not run
conditions are not met to allow
starting
check that the conditions allowing
starting are met (
5.2.a)
3. With the
key is turned to
«START» the light
or the control panel
come on, but the
starter motor is not
activated
– insuciently charged battery
malfunction on the starter relay
recharge the battery (
6.2.3)
contact Your Dealer
4. With the key
on «START», the
starter motor runs
but the engine does
not start
– insuciently charged battery
faulty fuel supply
faulty ignition
recharge the battery (
6.2.3)
check the level in the tank ( 5.3.3)
open the fuel stopcock (if present)
(
5.4.1)
– check the fuel lter
check that spark plug cap is
securely tted
check that the electrodes are clean
and have the correct gap
8. TROUBLESHOOTING