Specification Sheet
Information and product specications contained in this document are subject to change without notice. REV 2020-01
Specications
Tankless Electric Water Heater
Deionized
Stainless Steel, Nichrome and Engineered Plastics for All Wetted Components
TEMPERATURE RISE °F
MODEL NUMBER kW AMPS
RECOMMENDED
WIRE SIZE (CU)
1.0
GPM
1.5
GPM
2.0
GPM
3.0
GPM
4.0 GPM
T2 ONLY
VOLTS 240*
C
EX144T2 DI
15.0 64(2x32) 8 AWG – 65° 51° 34° 26°
C
EX144TC DI
15.0 64(2x32) 8 AWG † 65° 51° 34° –
C
EX190T2 DI
19.0 80(2x40) 8 AWG – 87° 65° 43° 32°
C
EX190TC DI
19.0 80(2x40) 8 AWG † 87° 65° 43° –
VOLTS 208 Single Phase
C
EX1608T2 DI
16.6 80(2x40) 8 AWG – 75° 57° 38° 28°
C
EX1608TC DI
16.6 80(2x40) 8 AWG † 75° 57° 38° –
VOLTS 277
EX160T2 DI
16.0 58(2x29) 10 AWG – 73° 55° 36° 27°
EX160TC DI
16.0 58(2x29) 10 AWG † 73° 55° 36° –
EX200TC DI
20.0 72(2x36) 8 AWG † 91° 68° 46° –
Dual Module
Sux Denitions
TC Staged heating elements
T2 Parallel heating elements
10.68
10.12
ELECTRICAL
CONNECTION (2)
.94
1.77
1.41
4.00
4.32
UTLET
INLET
TEMPERATURE RISE °F
MODEL NUMBER kW
AMPS
PER PHASE
RECOMMENDED
WIRE SIZE (CU)
2.0
GPM
3.0
GPM
4.0
GPM
5.0 GPM
T3 ONLY
VOLTS 208 Three Phase Delta
EX180T2T DI
18.0 50/phase 6 AWG 61° 41° 31° –
EX180T3 DI
18.0 50/phase 6 AWG 61° 41° 31° 25°
EX240T2T DI
24.0 67/phase 6 AWG 82° 55° 41° –
EX240T3 DI
24.0 67/phase 6 AWG 82° 55° 41° 33°
VOLS 240*
EX280T2T DI
28.5 119(3x40) 8 AWG † 64° 48° –
VOLTS 480Y/277 Three Phase Wye - neutral leg required
EX180T2T-277 DI
18.0 22/phase 10 AWG 61° 41° 31° –
EX240T2T-277 DI
24.0 29/phase 10 AWG 82° 55° 41° –
EX240T3-277 DI
24.0 29/phase 10 AWG 82° 55° 41° 33°
EX320T2T-277 DI
32.0 39/phase 8 AWG † 73° 55° –
EX320T3-277 DI
32.0 39/phase 8 AWG † 73° 55° 44°
VOLTS 480 Three Phase Delta
ED020480T2T DI
20.0 24/phase 10 AWG 68° 46° 34° –
ED024480T2T DI
24.0 29/phase 10 AWG 82° 55° 41° –
ED032480T2T DI
32.0 38/phase 6 AWG 109° 73° 55° –
Triple Module
Sux Denitions
T2T Staged heating elements
T3 Parallel heating elements
18.19
12.14
.90
1.87
1.30 7.02
INLET
OUTLET
ELECTRICAL CONNECTION
Single Module
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according
to a 240V applied voltage. Check with local ofcials prior to derating the electrical infrastructure.
† Temperature electrically limited to factory preset not-to-exceed temperature.
"C" indicates evaluation and compliance to Underwriters Laboratories (UL) under CAN/CSA-C22.2 No.
64/No
. 88.
9.73
1.12
1.50
5.25
.81
3.00
INLET
OUTLET
TEMPERATURE RISE °F
MODEL NUMBER kW AMPS
RECOMMENDED
WIRE SIZE (CU)
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
2.0
GPM
VOLTS 120
C
SPEX1812T DI
1.8 15 14 AWG 25° 16° 12° 8° 6°
C
SPEX2412T DI
2.4 20 14 AWG 33° 22° 16° 11° 8°
C
SPEX3012T DI
3.0 25 12 AWG 41° 27° 20° 14° 10°
C
SPEX3512T DI
3.5 29 10 AWG 48° 32° 24° 16° 12°
VOLTS 240*
C
SPEX35T DI
3.5 15 14 AWG 48° 32° 24° 16° 12°
C
SPEX48T DI
4.8 20 14 AWG 66° 44° 33° 22° 16°
C
SPEX55T DI
5.5 23 12 AWG 75° 50° 38° 25° 19°
C
SPEX65T DI
6.5 27 10 AWG 89° 59° 44° 30° 22°
C
SPEX75T DI
7.5 32 10 AWG 102° 68° 51° 34° 26°
C
SPEX95T DI
9.5 40 8 AWG † 87° 65° 43° 32°
VOLTS 208 Single Phase
C
SPEX8208T DI
8.3 40 8 AWG † 76° 57° 38° 28°
VOLTS 277
SPEX3277T DI
3.0
11 14 AWG 41° 27° 20° 14° 10°
SPEX4277T DI
4.1 15 14 AWG 56° 37° 28° 19° 14°
SPEX60T DI
6.0 22 12 AWG 82° 55° 41° 27° 20°
SPEX80T DI
8.0 29 10 AWG 109° 73° 55° 36° 27°
SPEX90T DI
9.0 33 10 AWG † 82° 61° 41° 31°
SPEX100T DI
10.0 36 8 AWG † 91° 68° 46° 34°