Installation guide
   9   EX9001-48 
TEMPERATURE RISE AT SPECIFIED FLOW RATE, DEGREES F: 
"SINGLE 
"FLOW 
 POINT" 
CONTROLLED" 
"THERMOSTATIC" 
MODEL 
MODEL 
MODEL 
0.5 
GPM 
1.0 
GPM 
1.5 
GPM 
2.0 
GPM 
2.5 
GPM 
SP2412 
EX2412 
EX2412T 
33 
16 
11 
8 
6 
SP3012 
EX3012 
EX3012T 
41 
20 
14 
10 
8 
SP3512 
EX3512 
EX3512T 
48 
24 
16 
12 
9 
SP3208 
EX3208 
EX3208T 
41 
20 
14 
10 
8 
SP4208 
EX4208 
EX4208T 
56 
28 
19 
14 
11 
SP8208 
EX8208 
EX8208T 
* 
57 
38 
28 
14 
SP35 
EX35 
EX35T 
48 
24 
16 
12 
9 
SP48 
EX48 
EX48T 
65 
32 
21 
16 
13 
SP55 
EX55 
EX55T 
75 
38 
25 
19 
15 
SP65 
EX65 
EX65T 
* 
44 
30 
22 
18 
SP75 
EX75 
EX75T 
* 
51 
34 
26 
20 
SP95 
EX95 
EX95T 
* 
65 
43 
32 
26 
n/a 
n/a 
EX012240T 
* 
73 
52 
39 
31 
SP3277 
EX3277 
EX3277T 
41 
21 
14 
10 
8 
SP4277 
EX4277 
EX4277T 
56 
28 
19 
14 
11 
SP60 
EX60 
EX60T 
* 
41 
27 
20 
15 
SP80 
EX80 
EX80T 
* 
55 
36 
27 
22 
SP90 
EX90 
EX90T 
* 
61 
41 
31 
26 
SP100 
EX100 
EX100T 
* 
68 
46 
34 
27 
* Not enough water flow to activate the heater. 
6) “Thermostatic”. Water too cold.  Using the 
OUTLET BALL VALVE, slowly reduce water flow until the 
desired temperature is achieved.  Keep the INLET BALL 
VALVE fully “OPEN”. NEVER RESTRICT THE WATER 
FLOW USING THE INLET VALVE. The temperature is 
proportional to the flow through the heater; the lower 
the flow, the higher the temperature and vice versa. 
The heater is fully installed and ready for use.  
“Thermostatic”.  Water too hot. Turn the 
temperature adjustment screw counter-clockwise 
about 1/8 of a turn and wait 15-20 seconds.  If the 
temperature remains too hot, repeat this step until the 
desired temperature is achieved. The heater is fully 
installed and ready for use. 