Installation guide
   6   EX9001-48 
3) ELECTRICAL HOOK-UP 
 BEFORE BEGINNING ANY WORK ON THIS INSTALLATION, BE SURE THAT THE 
ELECTRICAL BREAKER IS “OFF” AND THAT ALL MOUNTING AND PLUMBING WORK HAS BEEN 
COMPLETED PER THESE INSTRUCTIONS. 
This heater must have its own independent circuit using insulated, UL listed, 3 wire cable (2 wire plus 
ground) of the appropriate size suitable for up to 75 degree C and protected by the correctly rated 
circuit breaker. Refer to the chart on page 7. 
 FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY, DEATH 
AND/OR PROPERTY DAMAGE. 
1) Power cable entry to the heater should be made 
through one of the “knock-out” holes located on the 
back plate or top/bottom ends of the unit. Use the 
appropriate strain relief fitting. 
2) The power leads are to be secured to the L1 and 
L2 or L and N connectors on the terminal block or 
relay. The ground lead is to be secured to the GND 
connector on the block or the green ground wire 
with the wire nut.  










