Installation guide
   3   EX9001-48 
1) MOUNTING THE UNIT TO THE WALL 
1) The heater should be mounted “under the sink” as close to the point of use as possible. “Single 
Point” will have the brass fittings on the top pointing “up”. “Flow Controlled” and “Thermostatic” will 
have the fittings on the bottom pointing “down”. 
2) The fittings must be pointed in 
the vertical direction and be at 
least 16 inches below the level of 
the hot water faucet. Make sure 
to leave a minimum of 8 inches 
service clearance at the end 
OPPOSITE the fittings. 
3)  Remove  the  cover  and  fasten 
to  the  wall  using  the  four 
mounting holes at each corner of 
the  back plate.    Make sure  the 
“UP” arrow on the circuit board is 
facing “UP”. Replace the cover.  
If you need any assistance from our Technical Service Department, make sure you can identify this water 
heater by having the model no:____________________ and serial no:________________________. 
Call 203-267-7890 or toll free: 800-543-6163. 