Product Overview
Series 1
Thermostatic
14
Information and product specifications contained in this document are subject to change without notice.
Point of Use “Thermostatic”
Micro Processing Temperature Control
Specifications
Electric Tankless Hot Water Heater
TEMPERATURE RISE °F
MODEL NUMBER
kW
AMPS
TURN
ON
(GPM)
REC’D
WIRE SIZE
(CU)
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
2.0
GPM
VOLTS 120
C
EX2412T
2.4kW 20A 0.3 12 AWG 33° 22° 16° 11° 8°
C
EX2412T EE
2.4kW 20A 0.3 12 AWG 33° 22° 16° 11° 8°
C
EX2412T FS
2.4kW 20A 0.3 12 AWG 33° 22° 16° 11° 8°
C
EX2412T S
2.4kW 20A 0.3 12 AWG 33° 22° 16° 11° 8°
C
EX3012T
3.0kW 25A 0.3 10 AWG 41° 27° 20° 14° 10°
C
EX3012T EE
3.0kW 25A 0.3 10 AWG 41° 27° 20° 14° 10°
C
EX3012T FS
3.0kW 25A 0.3 10 AWG 41° 27° 20° 14° 10°
C
EX3012T S
3.0kW 25A 0.3 10 AWG 41° 27° 20° 14° 10°
C
EX3512 T
3.5kW 29A 0.3 10 AWG 48° 32° 24° 16° 12°
C
EX3512 T EE
3.5kW 29A 0.3 10 AWG 48° 32° 24° 16° 12°
C
EX3512 T FS
3.5kW 29A 0.3 10 AWG 48° 32° 24° 16° 12°
C
EX3512 T ML
3.5kW 29A 0.3 10 AWG 48° 32° 24° 16° 12°
C
EX3512 T S
3.5kW 29A 0.3 10 AWG 48° 32° 24° 16° 12°
VOLTS 240*
C
EX35T
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16° 12°
C EX35T (derated 208V perf.) 2.7kW 13A 0.3 14 AWG 37° 24° 18° 1.5° 9°
C
EX35T EE
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16° 12°
C
EX35T FS
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16° 12°
C
EX35T ML
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16° 12°
C
EX35T S
3.5kW 15A 0.3 14 AWG 48° 32° 24° 16° 12°
C
EX48T
4.8kW 20A 0.3 12 AWG 64° 42° 31° 21° 16°
C EX48T (derated 208V perf.) 3.6kW 17A 0.3 12 AWG 49° 33° 25° 16° 12°
C
EX48T EE
4.8kW 20A 0.3 12 AWG 64° 42° 31° 21° 16°
C
EX48T FS
4.8kW 20A 0.3 12 AWG 64° 42° 31° 21° 16°
C
EX48T ML
4.8kW 20A 0.3 12 AWG 64° 42° 31° 21° 16°
C
EX48T S
4.8kW 20A 0.3 12 AWG 64° 42° 31° 21° 16°
C
EX55T
5.5kW 23A 0.3 10 AWG 75° 50° 38° 25° 19°
C EX55T (derated 208V perf.) 4.1kW 20A 0.3 10 AWG 56° 38° 28° 19° 17°
C
EX55T EE
5.5kW 23A 0.3 10 AWG 75° 50° 38° 25° 19°
C
EX55T FS
5.5kW 23A 0.3 10 AWG 75° 50° 38° 25° 19°
C
EX55T ML
5.5kW 23A 0.3 10 AWG 75° 50° 38° 25° 19°
C
EX55T S
5.5kW 23A 0.3 10 AWG 75° 50° 38° 25° 19°
C
EX65T
6.5kW 27A 0.7 10 AWG – 59° 44° 30° 22°
C EX65T (derated 208V perf.) 4.9kW 24A 0.7 10 AWG – 44° 33° 22° 17°
C
EX65T EE
6.5kW 27A 0.7 10 AWG – 59° 44° 30° 22°
C
EX65T FS
6.5kW 27A 0.7 10 AWG – 59° 44° 30° 22°
C
EX65T ML
6.5kW 27A 0.3 10 AWG + 59° 44° 30° 22°
C
EX65T S
6.5kW 27A 0.7 10 AWG – 59° 44° 30° 22°
C
EX75T
7.5kW 32A 0.7 8 AWG – 68° 51° 34° 26°
C EX75T (derated 208V perf.) 5.6kW 27A 0.7 8 AWG – 51° 38° 26° 19°
C
EX75T EE
7.5kW 32A 0.7 8 AWG – 68° 51° 34° 26°
C
EX75T FS
7.5kW 32A 0.7 8 AWG – 68° 51° 34° 26°
C
EX75T ML
7.5kW 32A 0.3 8 AWG + 68° 51° 34° 26°
C
EX75T S
7.5kW 32A 0.7 8 AWG – 68° 51° 34° 26°
C
EX95T
9.5kW 40A 0.7 8 AWG – 87° 65° 43° 32°
C EX95T (derated 208V perf.) 7kW 34A 0.7 8 AWG – 64° 48° 32° 24°
C
EX95T EE
9.5kW 40A 0.7 8 AWG – 87° 65° 43° 32°
C
EX95T FS
9.5kW 40A 0.7 8 AWG – 87° 65° 43° 32°
C
EX95T ML
9.5kW 40A 0.3 8 AWG – 87° 65° 43° 32°
C
EX95T S
9.5kW 40A 0.7 8 AWG – 87° 65° 43° 32°
EX012240T
11.5kW 48A 0.7 6 AWG – 104° 79° 52° 39°
EX012240T (derated 208V perf.) 8.7kW 42A 0.7 6 AWG – 79° 59° 39° 30°
EX012240T EE
11.5kW 48A 0.7 6 AWG – 104° 79° 52° 39°
EX012240T FS
11.5kW 48A 0.7 6 AWG – 104° 79° 52° 39°
EX012240T ML
11.5kW 48A 0.3 6 AWG – 104° 79° 52° 39°
EX012240T S
11.5kW 48A 0.7 6 AWG – 104° 79° 52° 39°
TEMPERATURE RISE °F
MODEL NUMBER
kW AMPS
TURN
ON
(GPM)
REC’D
WIRE
SIZE (CU)
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
2.0
GPM
VOLTS 208 Single Phase
C
EX3208T
3.0kW 15A 0.3 14 AWG 41° – – – –
C
EX3208T ML
3.0kW 15A 0.3 14 AWG 41° – – – –
C
EX4208T
4.1kW 20A 0.3 12 AWG 56° 37° 28° 18° 14°
C
EX4208T EE
4.1kW 20A 0.3 12 AWG 56° 37° 28° 18° 14°
C
EX4208T FS
4.1kW 20A 0.3 12 AWG 56° 37° 28° 18° 14°
C
EX4208T ML
4.1kW 20A 0.3 12 AWG 56° 37° 28° 18° 14°
C
EX4208T S
4.1kW 20A 0.3 12 AWG 56° 37° 28° 18° 14°
C
EX8208T
8.3kW 40A 0.7 8 AWG – 76° 57° 38° 28°
C
EX8208T EE
8.3kW 40A 0.7 8 AWG – 76° 57° 38° 28°
C
EX8208T FS
8.3kW 40A 0.7 8 AWG – 76° 57° 38° 28°
C
EX8208T ML
8.3kW 40A 0.3 8 AWG + 76° 57° 38° 28°
C
EX8208T S
8.3kW 40A 0.7 8 AWG – 76° 57° 38° 28°
VOLTS 277
EX3277T
3.0kW 11A 0.3 14 AWG 41° – – – –
EX3277T EE
3.0kW 11A 0.3 14 AWG 41° – – – –
EX3277T FS
3.0kW 11A 0.3 14 AWG 41° – – – –
EX3277T ML
3.0kW 11A 0.3 14 AWG 41° – – – –
EX3277T S
3.0kW 11A 0.3 14 AWG 41° – – – –
EX4277T
4.1kW 14.8A 0.3 14 AWG 56° 37° 28° 19° 14°
EX4277T EE
4.1kW 14.8A 0.3 14 AWG 56° 37° 28° 19° 14°
EX4277T FS
4.1kW 14.8A 0.3 14 AWG 56° 37° 28° 19° 14°
EX4277T ML
4.1kW 14.8A 0.3 14 AWG 56° 37° 28° 19° 14°
EX4277T S
4.1kW 14.8A 0.3 14 AWG 56° 37° 28° 19° 14°
EX60T
6.0kW 22A 0.7 10 AWG – 55° 41° 27° 20°
EX60T EE
6.0kW 22A 0.7 10 AWG – 55° 41° 27° 20°
EX60T FS
6.0kW 22A 0.7 10 AWG – 55° 41° 27° 20°
EX60T ML
6.0kW 22A 0.3 10 AWG 81° 55° 41° 27° 20°
EX60T S
6.0kW 22A 0.7 10 AWG – 55° 41° 27° 20°
EX80T
8.0kW 29A 0.7 10 AWG – 73° 55° 36° 27°
EX80T EE
8.0kW 29A 0.7 10 AWG – 73° 55° 36° 27°
EX80T FS
8.0kW 29A 0.7 10 AWG – 73° 55° 36° 27°
EX80T ML
8.0kW 29A 0.3 10 AWG + 73° 55° 36° 27°
EX80T S
8.0kW 29A 0.7 10 AWG – 73° 55° 36° 27°
EX90T
9.0kW 33A 0.7 8 AWG – 82° 61° 41° 31°
EX90T EE
9.0kW 33A 0.7 8 AWG – 82° 61° 41° 31°
EX90T FS
9.0kW 33A 0.7 8 AWG – 82° 61° 41° 31°
EX90T ML
9.0kW 33A 0.3 8 AWG + 82° 61°
41° 31°
EX90T S
9.0kW 33A 0.7 8 AWG – 82° 61° 41° 31°
EX100T
10.0kW 36A 0.7 8 AWG – 91° 68° 46° 34°
EX100T EE
10.0kW 36A 0.7 8 AWG – 91° 68° 46° 34°
EX100T FS
10.0kW 36A 0.7 8 AWG – 91° 68° 46° 34°
EX100T ML
10.0kW 36A 0.3 8 AWG + 91° 68° 46° 34°
EX100T S
10.0kW 36A 0.7 8 AWG – 91° 68° 46° 34°
Suffix Definitions
EE Meets ANSI Z358.1 emergency
eye/face wash tepid water requirements
FS Factory set ambient to 180°
ML Multi lavs 0.3 turn on. staged up to
4 lavs 105°-110° temp setting
S Sanitation 180°
9.67
5.22
1.1
1 1.50
3.00
.81
11.81
9.84
7.30
11.08
1.07 4.17 1.50
5.91
NEMA
4/4X
INLETOUTLET
4X Ø.25
MOUNTING
HOLES
INLETOUTLET
85% reduction
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL
standards the rating plate and installation instructions will all be according to a 240V applied voltage.
Check with local officials prior to derating the electrical infrastructure.
+Temperature electronically limited to factory preset not to exceed temperature.
“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under
CAN/CSA-C22.2 No. 64/No. 88.