Manual ED020-032 T3-T2T

EX09001-48 REV 8
3
GENERAL
To obtain optimum performance and energy savings from your Eemax heater, the unit should be
located as near as possible to the point of use. The unit must only be installed in a vertical
position with the inlet and outlet at the bottom.
The power is activated by individual electronic flow switches located in each of the three heating
modules. These modules will be damaged by excessive heat; do not solder any pipes that are in
contact with the heater.
Also ensure pipes are clear of installation debris before fitting the heater, otherwise the flow
switches could jam in the β€œon” position. The unit must be connected to its own individual electric
circuit protected by a suitably rated three pole breaker. The maximum voltage which can be
applied across any heating module is 480 volts.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause DEATH,
SERIOUS BODILY INJURY OR PROPERTY DAMAGE. Refer to this manual for
assistance or consult the local electric utility for further information.
The unit is supplied with 1/2” compression water fittings.
Under no circumstances use a propane or plumber’s torch on pipe which is connected to
the heater, as serious damage to the electronic flow switch will result. Do not use pipe
dope.
WARNING
Failure to ground the system may result in death or serious injury.