Installation Guide and Manual

10
COMMISSIONING THE WATER HEATER
CAUTION
BEFORE SWITCHING THE ELECTRICAL BREAKER “ON”, MAKE SURE THE INLET AND
OUTLET BALL VALVES ARE FULLY OPEN AND WATER IS FLOWING THROUGH ALL
POINTS OF USE FOR A MINIMUM OF 5 MINUTES AT A MINIMUM 15 GPM. Open and
close drain valve 3 times while purging to remove any lodged air bubbles. DO NOT
SWITCH THE BREAKER “ON” IF THERE IS ANY POSSIBILITY THE WATER IN THE HEATER
IS FROZEN.
After verifying the heater has been purged of air (see above)
turn the circuit breaker/disconnect “ON” and observe the
start-up sequence on the display. The LCD screen will display
the SETPOINT TEMPERATURE in degrees F.
Below the display are 4 push buttons that are used to control
the function of the heater. Press the UP or DOWN buttons to
establish your desired temperature. Refer to the CONTROL
FEATURES section of this manual for additional information.
SETPOINT
TEMP 120F