Installation Guide and Manual

7
PLUMBING HOOKUP
MUST FLUSH LINE A MINIMUM 5 MINUTES, AT A MINIMUM 15 GPM ON INITIAL START UP
The heater is equipped with NPT brass fittings.
Make sure ONLY NPT fittings are used for connection to this heater.
Connect the cold water line with the inlet connection
(RIGHT fitting)
Connect the outlet pipe with the outlet fitting
(LEFT fitting)
Do not reverse connections.
CAUTION
Never use pipe dope when making plumbing connections to this heater. Follow
standard industry practice with careful application of Teflon tape. Do not allow Teflon
tape to get into the heater.
CAUTION
Never solder any pipe connections while attached to this heater damage to the
heater will result. Doing this will void the warranty.
PRV VENT LOCATION. The PRV Vent is not a code
compliant pressure relief valve. Check local codes to
see if a code compliant T&P Relief Valve is required
in your installation.
HOT
WATER
OUT
COLD
WATER
IN