Installation Guide and Manual
5
ELECTRICAL HOOKUP
Eemax recommends your heater be installed or serviced by a licensed plumber and electrician.
WARNING
Before beginning any work on this installation, BE SURE THAT THE ELECTRICAL
BREAKER IS “OFF” AND THAT ALL MOUNTING AND PLUMBING WORK HAS BEEN
COMPLETED PER THESE INSTRUCTIONS.
This heater must have its own independent circuit using insulated, UL listed wire conductors of the appropriate size
suitable for up to 90° C and protected by the correctly rated circuit breaker.
See chart on next page.
Before starting any electrical work VERIFY there is
no power at the heater before proceeding
The power conductors are to be secured to the L1, L2 and L3 connectors on the terminal block (Fig. 1) or
contactor (Fig. 2). The ground is to be secured to the GND connector to the right of the terminal block.
Fig. 1
L1 L2 L3 GND
Fig. 2
L1 L2 L3 GND
WARNING
FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY,
DEATH AND/OR PROPERTY DAMAGE.