Specification Sheet

Information and product specications contained in this document are subject to change without notice. REV 2020-01
Specications
Electric Tankless Water Heater
AccuMix II
Ideal for Sensor or Metering Faucets – UPC 407.3 Compliant
TEMPERATURE RISE °F
MODEL NUMBER kW AMPS
RECOMMENDED
WIRE SIZE
(75° C/CU)
# OF 0.5
AERATORS
SUPPLIED/UNIT
TURN ON
(GPM)
0.3
GPM
0.5
GPM
1.0
GPM
1.5
GPM
VOLTS 120
C
AM004120T
3.5 29 10 AWG 1 0.3 80° 48° 24° 16°
VOLTS 240*
C
AM005240T
4.8 20 14 AWG 1 0.3 66° 33° 22°
AM005240T (derated 208V perf.)
3.6 17 14 AWG 1 0.3 49° 25° 16°
C
AM007240T
6.5 27 10 AWG 2 0.3 44° 30°
AM007240T (derated 208V perf.)
5.0 24 10 AWG 2 0.3 68° 34° 23°
C
AM010240T
9.5 40 8 AWG 3 0.3 65° 43°
AM010240T (derated 208V perf.)
7.5 36 8 AWG 3 0.3 51° 34°
C
AM012240T
11.5 48 8 AWG 4 0.3 79° 52°
AM012240T (derated 208V perf.)
8.7 42 8 AWG 4 0.3 59° 40°
VOLTS 277
AM004277T
4.1 15 14 AWG 1 0.3 56° 28° 19°
AM008277T
8.0 29 10 AWG 2 0.3 55° 36°
AM010277T
10.0 36 8 AWG 3 0.3 68° 46°
Warning: The temperature of this
heater has been Eemax factory
set at 105°F for handwashing
applications and must not be
adjusted. Tampering with any
adjustments will void warranty and
may cause a loss of compliance to
Uniform Plumbing Code 407.3. For
further information please contact
our technical support department
at 1-800-543-6163.
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a
208V to 240V single phase applied voltage. Check with local ofcials prior to derating the electrical infrastructure.
† Units are factory preset to 105°F.
"C" indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No.
64/No. 88.
13.72
5.23 3.99