Specifications

Manual Logos
EELA AUDIO Parmentierweg 3 12 Rev. 6 (July 2001)
5657 EH Eindhoven, the Netherlands Main v1.43
Possible functions for GPO-A and GPO-B (outputs) are:
None
Timer start, impulse contact closure
Timer start microphone, impulse contact closure
Timer start line channel 1, impulse contact closure
Timer start line channel 2, impulse contact closure
Timer start line channel 1 & 2, impulse contact closure
Call detect, contact closure on detecting an incoming telephone call
Controlroom microphone On
Studio microphone On
Split/rec Off / On
Set name
The name that will be displayed on the Logos desktop console, is limited to 8 characters.
Editor type
Possible options are:
No editor
No-editor system connected to Logos
Dalet GPIO
Client for Win 95/98 with faderstart / stop I/O on parallel port
X-track
Client with special PC Eela Audio software for controlling X-track, available on
request, please contact sales@eela.nl. With the use of special Eela Audio software,
control data can be used for implementation of your own control software.
Dalet serial
Client for NT with faderstart / stop by serial link for one play/record channel only.
Microphone tab
Here you can select the logic for the microphone: Controlroom or Studio microphone. The
difference is the control over speakers and signalisation. If Controlroom is selected the
speakers will mute upon opening the microphone fader to prevent feedback.