Specifications
Manual Logos
EELA AUDIO Parmentierweg 3 12 Rev. 6 (July 2001)
5657 EH Eindhoven, the Netherlands Main v1.43
Possible functions for GPO-A and GPO-B (outputs) are:
• None
• Timer start, impulse contact closure
• Timer start microphone, impulse contact closure
• Timer start line channel 1, impulse contact closure
• Timer start line channel 2, impulse contact closure
• Timer start line channel 1 & 2, impulse contact closure
• Call detect, contact closure on detecting an incoming telephone call
• Controlroom microphone On
• Studio microphone On
• Split/rec Off / On
Set name
The name that will be displayed on the Logos desktop console, is limited to 8 characters.
Editor type
Possible options are:
No editor
No-editor system connected to Logos
Dalet GPIO
Client for Win 95/98 with faderstart / stop I/O on parallel port
X-track
Client with special PC Eela Audio software for controlling X-track, available on
request, please contact sales@eela.nl. With the use of special Eela Audio software,
control data can be used for implementation of your own control software.
Dalet serial
Client for NT with faderstart / stop by serial link for one play/record channel only.
Microphone tab
Here you can select the logic for the microphone: Controlroom or Studio microphone. The
difference is the control over speakers and signalisation. If Controlroom is selected the
speakers will mute upon opening the microphone fader to prevent feedback.