Cut Sheet

Data Sheet S85001-0559 Issue 8
Not to be used for installation purposes. Page 3 of 4
Current Draw
Notes and Comments
1. Current values are shown in mA.
2. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used.
3. GE Security recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations.
4. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations.
5. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the
current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices.
6. Our industry has used ‘mean’ currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future.
Light output - (effective cd)
Percent of UL rating versus angle
0 10 20 30 40 50 60 70 80 90 100 110 120102030405060708090100110120
0
°
15
°
30
°
45
°
60
°
75
°
90
°
-15
°
-30
°
-45
°
-60
°
-75
°
Per Cent of UL Rating
dBA output
Notes
1. All values shown are dBA measured at 10 feet (3.01m); 2. UL464 values measured in
reverberation room; 3. Average and Peak values are measured in anechoic chamber.
EGC-HDVM Temporal Horn-strobe: High dB Setting EGC-HDVMH High cd Temporal Horn-strobe: High dB Setting
UL
Rating
15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd
RMS RMS RMS RMS RMS RMS RMS RMS
16 Vdc 147 190 316 372 341 399 506 570
16 Vfwr 189 253 417 451 487 578 670 711
EGC-HDVM Temporal Horn-strobe: High dB Setting EGC-HDVMH High cd Temporal Horn-strobe: High dB Setting
Typical
Current
15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd
RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean
16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551
20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414
24 Vdc 80 71 108 101 185 180 212 207 220 217 252 249 304 301 341 338
33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241
16 Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442
20 Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334
24 Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271
33 Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194
EGC-HDVM Temporal Horn-strobe: Low dB Setting EGC-HDVMH High cd Temporal Horn-strobe: Low dB Setting
Typical
Current
15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd
RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean
16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542
20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411
24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332
33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232
16 Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432
20 Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326
24 Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264
33 Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186
High dB
Setting
UL464 Average Peak
Temporal Steady
Temporal/
Steady
Temporal/
Steady
16 Vdc 79.8 83.2 90.6 93.6
24 Vdc 83.3 85.4 93.6 96.6
33 Vdc 85 87.8 95.7 98.7
Low dB
Setting
UL464 Average Peak
Temporal Steady
Temporal/
Steady
Temporal/
Steady
16 Vdc 75 79.3 86.3 88.7
24 Vdc 78 83 88.8 92.4
33 Vdc 80.9 85.9 91.8 95.1