Cut Sheet
FIRE ALARM EQUIPMENT
90 Fieldstone Court
||
||
| Cheshire, CT 06410
Ph: 203.699.3300
||
||
| Fx: 203.699.3108
www.edwards-signals.com
TECHNICAL INFORMATION
12-25
© Copyright 2004 Edwards
Feature Description
Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating.
Lens Optical grade polycarbonate (clear)
Mounting Flush mount: 2 1/2" inch (64mm) deep one-gang box
(indoor wall mount only) Surface mount: Edwards model 27193 surface mount box, wiremold box, or equivalent surface-mount box
With optional trim plate: one-gang, two-gang, four-inch square, octagonal, or European single-gang box
Wire Connections Screw terminals: single input for both horn and strobe, #18 to #12 AWG (0.75 mm
2
to 2.5 mm
2
) wire size
Operating Environment Indoor only: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity.
Agency UL 1971, UL 1638, UL 464, ULC S525, ULC S526, CE, FCC, (MEA, FM, CSFM pending).
Listings/Approvals (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.)
Strobe Output Selectable 15 cd, 30 cd, 75 cd, or 110 cd output or Selectable 95 - 177 cd output
Operating Voltage EG1-VM series strobes: Non-coded, filtered 16-33V DC or unfiltered 16-33V DC FWR
EG1-HD temporal horns: Non-coded, filtered 16-33V DC or unfiltered 16-33V DC FWR (or coded when set to steady)
EG1-P steady horns: Coded or non-coded, filtered 20-31V DC or unfiltered 20-27V FWR
EG1-HDVM series temporal tone horn/strobes: Non-coded, filtered 16-33V DC or unfiltered 16-33V DC FWR
(or coded (audible NAC only) when used with optional EG1M Genesis Signal Master)
Strobe Output Rating UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output
Strobe Flash Rate EG1-VM series strobes and EG1-HDVM series temporal horn/strobes: one flash per second synchronized with
optional EG1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within
200 milliseconds over thirty minutes on a common circuit without EG1M Genesis Signal Master)
Temporal setting (private mode only): synchronized to temporal output of horns on same circuit
Compatible EG1M, EG1M-RM
Synchronization Module
Horn Pulse Rate EG1-HD temporal-tone horns and EG1-HDVM series temporal-tone horn-strobes: temporal rate synchronized
with optional EG1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within
200 milliseconds over thirty minutes on a common circuit without EG1M Genesis Signal Master)
EG1-P steady-tone horns: continuous, steady tone only
Temporal Audible Pattern 1/2 sec ON, 1/2 sec OFF, 1/2 sec ON, 1/2 sec OFF, 1/2 sec ON, 1 1/2 sec OFF, then repeat cycle
2 3/4”
(70mm)
4 1/2”
(114mm)
27/32”
(21mm)
D-04