Cut Sheet
Data Sheet S85001-0611 Issue 1
Not to be used for installation purposes. Page 1 of 6
Fire & Life Safety
Analog/Addressable
Part of GE Security
Overview
Edwards intelligent modules are engineered to deliver high-perfor-
mance features, superb reliability, and unbeatable quality. From
control of ancillary equipment, to enhanced signaling functional-
ity, these products add fl exibility and powerful options to Edwards
Signaling intelligent systems.
Designed expressly for small buildings, Edwards Signaling modules
are addressable devices that are uniquely identifi ed on the system
by means of familiar rotary switches. Once registered, they share
data and update status information that determines how the sys-
tem behaves and how connected devices interact with one another.
Unique to Edwards Signaling modules is ground fault detection so
precise that it actually pinpoints the specifi c module where the wir-
ing problem has occurred. This saves hours of troubleshooting and
wire tracing. And only Edwards Signaling provides this important
feature!
The Edwards Signaling family of intelligent modules also offers
contractors and installers simple setup and installation, while
delivering options that take full advantage of intelligent fi re alarm
processing. With a microprocessor in each device, intelligence is
distributed throughout the system so that command decisions are
made instantly at the individual module, rather than bottlenecking
at the control panel.
This not only speeds event processing, it also makes a more robust
and reliable system – so robust, in fact, that when upgrading from
a conventional panel to a Edwards Signaling intelligent system,
you can usually use existing wiring – no twisted or shielded cable
required!
Intelligent Input-Output
Modules
Models: E-2WIRE, E-IDC1A,
E-IDC2B, E-IDCWS, E-ISO,
E-NAC, E-RLY, E-IDC1B
Standard Features
Class A-B Two-Wire Module
Acts as an interface between conventional two-wire smoke
detectors and the Edwards Signaling control panel.
Analog Class A Single Input Module
Used to connect a normally open, alarm, supervisory, or monitor
type dry contact initiating device circuit to the Edwards Signaling
control panel.
Analog Dual Input Module
Connects two normally open, alarm, supervisory, or monitor type
dry contact initiating device circuits to the Edwards Signaling
control panel.
Analog Dual Input Waterfl ow, Supervisory Module
Used to connect normally open waterfl ow alarm and supervisory
initiating device circuits to the Edwards Signaling control panel.
For Class B circuit operation.
Analog SLC Fault Isolator Module
Protects a Class A SLC from total collapse due to wire-to-wire
short circuits.
Analog NAC Module
Connects a supervised output circuit to a signal riser.
Analog Contact Relay Module
Provides one Form C dry relay contact and can be confi gured to
provide polarity reversal of its output.
Analog Single Input Mini Module
Connects a normally open, alarm, supervisory, or monitor type
dry contact initiating device circuit (IDC) to the Edwards Signaling
control panel. For Class B circuit operation.
•
•
•
•
•
•
•
•