Product Manual B

Ironworker Hydraulic Accessory Package Hydraulic Accessory Tool Power/Controls
Hydraulic Power Sources
Your Edwards 20 Ton or 40 Ton Shop Press is factory assembled and
tested for optimum performance when powered by Edwards Manufac-
turing Company rated hydraulic power supply.
The Shop Press is powered by either an Edwards Ironworker factory
installed Hydraulic Accessory Control Package or an Edwards Porta-
Power, 5hp, 3000psi, portable power unit.
ALTERNATE POWER SOURCES ARE NOT RECOMMENDED
AND MAY COMPROMISE MACHINE OPERATION, MACHINE
HYDRAULIC WARRANTY AND OPERATOR SAFETY.
Follow electrical connection installation instructions for power supply as
set forth within the Installation Manual of the Edwards Ironworker.
Powering with an Edwards Ironworker
Power selection controls are located adjacent to the starter box on the
feed side of the machine. Hydraulic quick connections and accessory
controls are located on the drop-off side or end cap of the machine.
With the Ironworker power off, install Shop Press hoses, power and control:
Install the Shop Press male and female accessory hydraulic hoses
to the ironworker male and female quick connect hydraulic ttings.
Both ttings have a detent ball setting that must be aligned to cou-
ple and uncouple hoses.
Remove the safety cap at the push button port. Attach the Shop
Press control OUT / IN, male Mil Spec control cable to the female
Mil Spec accessory control port at your Ironworkers Hydraulic Ac-
cessory package.
With all Ironworker and Press stations clear of hands, tools, tool-
ing, material or debris, power up the Ironworker by depressing the
green button on the starter box.
With the power on, your Ironworker machine will return to a neutral
position.
Turn the 3-position switch on the front of the machine case to the Ac-
cessory position. This operation disables the Ironworker and switches
control to the accessory hand control.
With all Shop Press work stations clear of hands, tools, tooling, material
or debris, test the Shop Press operation by depressing the OUT control
button. Once depressed, the hydraulic cylinder of the Shop Press will
extend to operate the accessory. Releasing pressure on the OUT control
button will stop the machine mid-operation. Return the tool to its starting
position by depressing the IN button.
When Disconnecting your Shop Press, simply reverse procedure.
Replace the safety cap at the push button port to restore power to
your Ironworker.
6
Powering with an Edwards Porta-Power
Your Edwards Porta-Power 5hp / 3000psi / Portable Power Unit will
power all your Edwards Hydraulic Accessories.
Follow electrical connection installation instructions as set forth within
these sections of the Porta-Power Installation Manual:
With the Edwards Porta-Power off, install accessory hoses, power and
control:
Install the male and female Shop Press hydraulic hoses to the Por-
ta-Power male and female quick connect hydraulic ttings adjacent
to the starterbox. Both ttings have a detent ball setting that must
be aligned to couple and uncouple hoses.
Remove the safety cap at the push button port. Attach the Shop
Press OUT / IN, male Mil Spec control cable to the female Mil Spec
accessory control port on the Porta-Power case.
With all Press stations clear of hands, tools, tooling, material or
debris, power up the Porta Power by depressing the green button
on the starter box.
Test the accessory operation by depressing the OUT control button.
Once depressed, the hydraulic cylinder of the Shop Press will extend to
operate the accessory. Releasing pressure on the OUT control button
will stop the machine mid-operation. Return the Shop Press to its start-
ing position by depressing the IN button.
If the machine fails to cycle, power down the Porta-Power by depressing
the red button on the starterbox, consult the trouble shooting section of
the Operations Manual.
Depress the red e-stop button on the hand control to kill power at the
Porta Power. To reset power, twist the e-stop button and push start but-
ton at Porta Power.
When disconnecting your Press, simply reverse procedure. Replace the
safety cap at the push button port to restore power to your Porta
Power.
7