Certifications 2

EDSYN GMBH EUROPA
Zentrum für Löt- und Entlötsysteme
EDSYN GMBH EUROPA, Postfach 1169, D-97888 Kreuzwertheim
24. März 2021
EDSYN GMBH EUROPA D-97892 Kreuzwertheim Finkenweg 2 (09342) 6413
(09342) 6417
8.) EXPOSURE CONTROLS / PERSONAL
PROTECTION
8.1.)
Control parameters
Exposure limits (EH40)
CAS No
Substance
mg/m³
fibres/ml
Category
Origin
7646-85-7 Zinc chloride,
fume
-
-
1
2
TWA(8h)
STEL(15min)
WEL
WEL
Additional
advice on limit values
:
8.2.) Exposure controls
Appropriate engineering controls:
Protective and hygiene measures:
Eye/face protection:
Hand protection:
Does not contain substances above concentration limits fixing an
occupational exposure limit.
If handled uncovered, arrangements with local exhaust ventilation have to
be used. Do not breathe gas/fumes/vapour/spray.
Remove contaminated, saturated clothing immediately. Draw up and
observe skin protection programme. Wash hands and face before breaks
and after work and take a shower if necessary. When using do not eat or
drink.
Suitable eye protection: googles. Safety glasses. For the protection
against direct skin contact, body protective clothing is essential (in addition
to the usual working clothes).
When handling with chemical substances, protective gloves must be worn
with the CE-label including the four control digits. The quality of the
protective gloves resistant to chemicals must be chosen as a function of
the specific working place concentration and quantity of hazardous
substances. For special purpose, it is recommended to check the
resistance to chemicals of the protective gloves mentioned above together
with the supplier of these gloves.
Additional protection measures for the hands:
Hand protection: DIN EN 374
-CR (polychloroprenes, Chloroprene rubber).
Thickness of glove material: 0,65 mm
penetration time (maximum wearing period): > 120 Min.
-NBR (Nitrile rubber):
Thickness of glove material: 0,4 mm
penetration time (maximum wearing period): > 480 Min.
Breakthrough times and swelling properties of the material must be taken
into consideration.
Take recovery periods for skin regeneration.
In the case of wanting to use the gloves again, clean them before taking
off and air them well.
Use gloves only once.
When handling with chemical substances, protective gloves must be worn
with the CE label including the four control digits.
Before using check leak tightness / impermeability.