User`s guide
Interface Panel182
English
Power Requirements
WARNI NG!
Connect the power plug to an outlet with the same rated voltage as the
printer. No other devices should be connected to this outlet, as
overheating could cause fire or electric shock. The printer draws 13 A at
100V, 11 A at 120 V, or 7 A at 220-240 V. Your printer requires a properly
grounded AC outlet. The grounding terminal on the power cable should
be connected to a good earth ground to prevent electric shock and fire.
In compliance with UL guidelines, “The appliance inlet is considered to
be the main disconnect device.”
Input Power North America 120 VAC; 50/60 Hz ±3%
Europe 220–240 VAC; 50/60 Hz ±3%
Latin America 115/120 VAC 50/60 Hz ±3%
220–240 VAC 50/60 Hz ±3%
Notes: Amperage capacity at least 1.2 times that used by
the printer.
Voltage
Fluctuation
Rate and Rated
Line Voltage
North America 120 VAC ±10%
Europe 220–240 VAC ±10%
Latin America 120 VAC ±10%
220–240 VAC ±10%
Notes: 10% of the rated line voltage for proper operation.
Frequency
Variation Rate
Within 50–60 ±3 Hz
Maximum
Electrical
Current
Required during operation is 13 amps for a 100 V, 11 amps
for a 120 V system and 7 amps for a 220–240 V system.
Noise-
generating
Equipment
Should not be connected to the same electrical outlet as
the printer.
Grounding Your printer requires a properly grounded AC outlet.