CMU 100 4 Channels Multimode Fiber Optic to RS232 Converter User Manual CMU 100 / 2.6.6.6.6.1.1.1.1 - 7 CMU 100 / 8.6.6.6.6.1.1.1.1 - 7 Company: Device: Ediseja 21 CMU 100 / 2.6.6.6.6.1.1.1.1 - 7 Document: Code: Version: User manual CMUMU261 V1 Date: 05.11.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 Content 1 PREFACE.......................................................................................................3 2 CMU 100 SYSTEM.........................................................................................6 2.1 DESCRIPTION..................................................................................................................... 6 2.1.1 SOFTWARE.............................................................................
PREFACE 1 PREFACE Liability statement We have checked the contents of this manual to ensure that the descriptions of both hardware and software are as accurate as possible. However, deviations may occur so that no liability can be accepted for any errors or omissions contained in the information given. The contents of this manual will be checked in periodical intervals, corrections will be made in the following editions. We reserve the right to make technical improvements without notice.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 Warnings In this paper the following terms are used: Danger indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken. Warning indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken. Caution indicates that minor personal injury or property damage can result if proper precautions are not taken.
PREFACE Warning! If device is damaged disconnect it from power supply! Send it to the manufacturer for inspection. Warning! Connect to earth before attaching power supply! Company: Device: Ediseja 21 CMU 100 / 2.6.6.6.6.1.1.1.1 - 7 Document: Code: Version: User manual CMUMU261 V1 Date: 05.11.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 2 CMU 100 SYSTEM 2.
DESCRIPTION Hardware settings All settings on the device can be made from outside by a DIL switch. It is not necessary to open the housing. Picture 1: CMU 100 system general diagram Company: Device: Ediseja 21 CMU 100 / 2.6.6.6.6.1.1.1.1 - 7 Document: Code: Version: User manual CMUMU261 V1 Date: 05.11.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 3 4 CHANNELS MULTIMODE FIBER OPTIC TO RS232 CONVERTER 3.1 DESCRIPTION This device contains four full duplex 820 nm wave lenght multimode fiber optic and four RS232 interface. Data is send from one fiber optic to one RS232 port and vice versa. Device has four independent channels. Wide power supply voltage allows connection to all common station batteries. Additionaly it can be also connected to standard AC voltages.
APPEARANCE 3.3 APPEARANCE Picture 2: Front view (left) & bottom view (right) 3.4 HARDWARE DESCRIPTION This configuration of device is made from main board (power supply, switches and logic switch), four fiber optic interface boards and four RS232 interface boards. 3.4.1 MAIN BOARD Power LED indicates that device is turned on. The right LEDs of one port shows activity on receive (Rx) line and the left one shows activity on transmit (Tx) line.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 Switch 5 6 7 8 Description Echo port 5 Echo port 6 Echo port 7 Echo port 8 Position OFF Echo off Echo off Echo off Echo off Position ON Echo on Echo on Echo on Echo on Default position OFF OFF OFF OFF Ports configuration Port 1 Interface FO MM 3.4.2 2 3 4 5 6 7 8 FO MM FO MM FO MM RS232 RS232 RS232 RS232 RS232 INTERFACE BOARD Description Single, nonisolated, full duplex, RS232 port with DB9 female connector.
HARDWARE DESCRIPTION 3.4.3 MULTIMODE FIBER OPTIC INTERFACE BOARD Description Single, full duplex, multimode, fiber optic port with ST connectors with positive or negative logic. Hardware settings For proper functioning of that board, optic logic must be set: Fiber optic logic settings Switch SW1 Light in idle state 1 2 3 4 Positive logic OFF OFF ON OFF ON Negative logic ON ON OFF ON OFF Picture 4: Multimode fiber optic interface board appearance Company: Device: Ediseja 21 CMU 100 / 2.6.6.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 4 SCHEMATIC Picture 5: General diagram Page: Company: Device: 12 Ediseja 21 CMU 100 / 2.6.6.6.6.1.1.1.1 - 7 Document: Code: Version: User manual CMUMU261 V1 Date: 05.11.
INSTALLATION 5 INSTALLATION 5.1 INSTALLATION Warning! Hazardous voltage is present inside the device during operation. Disregarding of safety rules can result in severe personal injury or property damage. Only qualified personnel may work with described devices after being familiar with warnings and safety notices in this paper and other safety regulations.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 Picture 6: left. installation, right: deinstallation Page: Company: Device: 14 Ediseja 21 CMU 100 / 2.6.6.6.6.1.1.1.1 - 7 Document: Code: Version: User manual CMUMU261 V1 Date: 05.11.
COMMISSIONING & MAINTENACE 6 COMMISSIONING & MAINTENACE 6.1 COMMISSIONING Warning! Hazardous voltage is present inside the device during operation. Disregarding of safety rules can result in severe personal injury or property damage. Only qualified personnel may work with described device after being familiar with warnings and safety notices in this paper and other safety regulations. Following instruction must be taken into consideration: 6.
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 7 TECHNICAL DATA Power supply Rated voltage Permissible voltage range Input current Type 2 Type 8 DC 110 - 250 V 48 - 60 V AC 230 V 48 V DC 88 - 300 V 38 - 72 V AC 70 - 264 V 30 - 50 V DC 50 - 30 mA 100 - 80 mA AC 50 mA 130 mA Fuse (internal) 2AT Power supply indicator green LED marked PWR Voltage dips 20 ms Connector type screw type „MSTB“ Phoenix 2pin Wire crossection 0,5 – 2,5 mm 2 Communication port RS232 (interface ty
TECHNICAL DATA Communication port Multimode Fiber Optic (interface type 6) Speed up to 230 k BAUD Input 1 receiver (grey connector) Output 1 transmitter (white connector) Logic light ON or OFF in idle state set by switch (see table) Number of ports 1 Distance up to 500 m Connector type ST * slowest interface defines device's maximum speed Device 0,55 kg Weight Dimensions (see picture) (H) (D) (W) 105 mm 111 mm + connectors 85 mm Temperature range 0 °C to +55 °C Humidity operating up
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 8 DIMENSIONS Picture 7: Dimensions Page: Company: Device: 18 Ediseja 21 CMU 100 / 2.6.6.6.6.1.1.1.1 - 7 Document: Code: Version: User manual CMUMU261 V1 Date: 05.11.
ORDERING 9 ORDERING ORDERING NUMBER: CMU 100 / c . c . c . c . c . c . c . c . c - c . c Mother Board + Enclosure + : Power supply: 88 - 350 V DC or 70 - 264 V AC 2 ports converters (no echo possible, mark Function as 0) ............................................... 1 2 to 8 ports converters, star couplers, ... (echo possible) ................................................... 2 Power supply: 38 - 72 V DC or 30 - 50 V AC 2 ports converters (no echo possible, mark Function as 0) .....................
CMU 100 - 4 Channels Multimode Fiber Optic to RS232 Most common devices: CMU 100 / 1.6.1 - 0 - 1 ch converter multimode fiber optic to RS232, high voltage power supply CMU 100 / 1.5.1 - 0 - 1 ch converter RS485 to RS232, 19k2-115k BAUD, high voltage power supply CMU 100 / 1.5.6 - 0 - 1 ch converter RS485 to multimode fiber optic, high voltage power supply CMU 100 / 2.1.1.1 - 2 - 3 channel star coupler RS232 to 2 x RS232, high voltage power supply CMU 100 / 2.1.6.