3.6.4 Test Setup
Transmitter Radiated Unwanted Emissions (below 1GHz)
Magnetic field tests shall be performed in the frequency range of 9 kHz to 30 MHz using a calibrated loop
antenna. Electric field tests shall be performed in the frequency range of 30 MHz to 1000 MHz using a
calibrated bi-log antenna.
Transmitter Radiated Unwanted Emissions (Above 1GHz)
Electric field tests shall be performed in the frequency range of 1 GHz to 10th harmonic of highest
fundamental frequency or 40 GHz using a calibrated horn antenna.
3.6.5 Transmitter Radiated Unwanted Emissions (Below 30MHz)
All amplitude of spurious emissions that are attenuated by more than 20 dB below the permissible value has
no need to be reported.