8.3 Radiated Emission Limits
Limits for radiated disturbance of Class A ITE at
a measuring distance of 10 m
Frequency
MHz
Field Strength
dB(ӴV/m)
30 to 230 40
230 to 1 000 47
NOTES
1 The lower limit shall apply at the transition frequency.
2 Additional provisions may be required for cases where
interference occurs.
Limits for radiated disturbance of Class B ITE at
a measuring distance of 10 m
Frequency
MHz
Field Strength
dB(ӴV/m)
30 to 230 30
230 to 1 000 37
NOTES
1 The lower limit shall apply at the transition frequency.
2 Additional provisions may be required for cases where
interference occurs.