Specifications

INTERFACE
Left knob (SX)
For power adjustment during manual operation and temperature adjustment during automatic operation. The operating mode may be set
using the A/M key on the central panel. The display shows the power or temperature set.
Right knob (DX)
F
or room air flow adjustment, which in any case cannot be set lower than the minimum necessary to ensure cooling of the internal stove
parts.
Panel On/Off key
To turn the stove on or off.
Panel A/M key
For switching the stove from manual to automatic operation and vice versa.
Panel "hourglass" key
For setting the programmed on/off times.
Display unit messages:
Ac: Ignition stage (flame appearance).
Ar: second Ignition stage (flame stabilizing) before the operating stage.
Off: shutdown stage (10 minutes).
P1 or P2 or P3: power level set.
8-29: temperature set for automatic operation.
H1...H7: stoppage problem identification number (see p. 11).
Pu: automatic combustion chamber cleaning under way.
nn: motor stopping; wait a few tens of seconds before entering other commands.
When the stove is on standby, the display shows the power level or temperature at which it will start up again, and the time (flashing).
OPERATION
Make sure the switch on the electric socket is set to 1
Before ignition.
1st Ignition: contact your local TAC (technical assistance centre, for information phone our toll-free number from Italy) to calibrate the stove
according to the pellets used and conditions of use.
The first few times the stove is ignited there may be a slight smell of paint, which disappears rapidly
.
Before ignition, check:
==> The stove has been installed correctly (see pages 7-8 ).
==> The power supply.
==> The door is closed.
==> The combustion chamber is clean.
==> The display shows standby (flashing power or temperature).
Hold the ON/OFF key down for at least two seconds: the stove will automatically start loading pellets to start combustion (the display
shows Ac). No flames appear for the first few minutes. Ac changes into Ar when the flame appears.
SCREW FEEDER LOADING.
If the pellet hopper empties completely
, press the On/Off and A/m keys together to fill the screw feeder
.
This must be done before igniting the stove again if it has shut down due to running out of pellets.
It is normal for a few pellets to be left in the hopper, which the screw feeder is not able to pick up.
left knob
right knob
INSTALLATION INSTRUCTIONS
panel
9