DISPLAY-CONTROL PANEL/SAFETY DEVICES
POSSIBLE CAUSES OF SHUTDOWN
If the stove shuts down, the reason is shown on the display.
H1 low pressure alarm: problem connected with air circulation.
H2 Smoke expulsion motor failure.
SF (H3) flame stop.
AF (H4) ignition failed.
H5 power failure stoppage.
H6 thermocouple failure or disconnection.
H7 excessive smoke temperature.
The message is displayed until the ON/OFF key on the panel is pressed after leaving the stove to shut down for ten minutes.
Do not restart the stove until the problem has been looked into and the cause removed.
In the event of problems
To start the stove up again after a shutdown, let the shutdown procedure end (10 minutes marked by a beep) then press the ON/OFF
key.
Never unplug the stove while it is shutting down due to problems.
It is important to report what the panel says to the TAC (technical assistance centre).
SAFETY DEVICES
THERMOCOUPLE:
on the smoke outlet. It measures the smoke temperature.
It controls the ignition, operating and shutdown stages according to the parameters set.
AIR FLOW SENSOR:
on the intake duct. It trips when the flow of combustion air is not correct, therefore causing low pressure problems in the smoke circuit.
It turns the stove off and displays an "H1" alarm if the firebox door is open, the smoke circuit is blocked or the smoke outlet pipe is
blocked.
SAFETY THERMOSTAT:
It trips if the temperature inside the stove is too high.
It stops pellet loading, thus causing the stove to go out.
SUGGESTIONS IN THE EVENT OF PROBLEMS
* Remember that the flame appears about seven minutes later and the ignition stage in any case lasts about a quarter of an hour.
11
PROBLEM POSSIBLE CAUSE SOLUTIONS
display-control panel off and buttons
not working
no mains voltage
- make sure the power cord is con-
nected
remote control (optional) not working
excessive distance from stove - move nearer to stove
remote control batteries - check and change if necessary
ignition failure
build up of unburnt material in com
-
bustion chamber
- clean combustion chamber
outlet air not hot too much soot in heat exchanger
- clean the heat exchanger from insi-
de the firebox
no flame appears *
the screw feeder has not been filled
(p. 9)
- fill it