Operation Manual

- 20 -
INTERFACE
Left knob (SX)
For power adjustment during manual operation and temperature adjustment during automatic operation. The operating mode may
be set using the A/M key on the central panel. The display shows the power or
temperature set.
Right knob (DX)
For room air ow adjustment, which in any case cannot be set lower than the minimum necessary to ensure cooling of the internal
stove parts.
Panel On/Off key
To turn the stove on or off.
Panel A/M key
For switching stove operation from manual to automatic and vice versa.
Only on IRIS WITH WEEKLY PROGRAMMER
Panel “hourglass” key
For setting the programmed on/off times
left knob
panel
right knob
Display unit messages
Ac: Ignition stage (ame appearance)
Ar: second Ignition stage (ame stabilizing) before the operating stage
Of: shutdown stage
P1 o P2 o P3: power level set
8-29: temperature set for automatic operation
H1..H7: stoppage problem identication number (see page 24)
Pu: automatic combustion chamber cleaning under way
ŋŋ: motor stopping; wait a few tens of seconds before entering other commands.
When the stove is on standby, this ashes to show the mode it will restart in and when.
OPERATION
Before ignition. Control to put ON 1 the switch.
1st ignition: contact your dealer to calibrate the stove according to the pellets used and conditions of use.
The rst few times the stove is ignited there may be a slight smell of paint, which disappears rapidly.
Before ignition, check:
- The stove has been installed correctly (see pages 17-18)
- The electric power supply.
- The door closes.
- The combustion chamber is clean.
- The display shows standby (ashing power or temperature).
Hold the ON/OFF key down for at least two seconds: the stove will automatically start loading pellets to start combustion (the
display shows Ac). No ames appear for the rst few minutes. Ac changes into Ar when the ame appears.
SCREW FEEDER LOADING.
If the pellet hopper empties completely, press the “hourglass” key for a few seconds.
This must be done before igniting the stove again if it has shut down due to running out of pellets.
It is normal for a few pellets to be left in the hopper, which the screw feeder is not able to pick up.
IGNITION
Automatic ignition
Hold the ON/OFF key down for two seconds with the stove on standby to start the ignition procedure. The word START appears
on the display for a few minutes (the ignition procedure does not actually take a preset time: it is automatically shortened if the
electronics detect that certain tests are passed). The ame appears after about ve minutes. It is normal for a little smoke to be
seen in the combustion chamber before the ame appears. “Ar” appears on the display until the ame stabilizes.
ENGLISH
ENGLISH