Configure Hostname, SNMP and Remote Logging
The 4300T can be managed remotely by an SNMP network management system
such as HP Openview. The 4300T supports SNMPv1 or SNMPv3 and MIB-II
(RFC1213). All MIB-II variables are read only. The MIB variables sysContact and
sysLocation are set by the web GUI.
Messages generated by the 4300T can
be sent to a remote log server.
The configuration screen is reached
through the Configuration Menu:
A. Select System.
B. Select System Overview.
C. Select Services Configuration.
Configure SNMP
A. Select the Enable SNMP v1 or
v3 checkbox. If using SNMPv1
enter the Read-Only
Community. If using SNMPv3
enter the User Name,
Passphrase and Security
method.
B. Enter the System Location.
This is a comment string that
can be used to indicate the
physical location of the 4300T.
By default, no value is set.
C. Enter the System Contact.
This is the administrative contact information for the 4300T. By default, no
value is set.
D. Enter the SNMP Port.
This is the port that the 4300T uses for SNMP communications with the
network management system. The default is 161.
E. Press Submit.
Disable SNMP
A. Select System.
B. Select System Overview.
C. Select Services Configuration.