Owner's Manual

5
ELECTRIC SHOCK HAZARD!
Electrical Requirements
Before you move your beverage cooler into its final location, it is important to make sure you
have the proper electrical connection:
A standard electrical supply (115 V, 60Hz), properly grounded in accordance with the National
Electrical Code and local codes and ordinances, is required.
It is recommended that a separate circuit, serving only your beverage cooler, be provided. Use
outlets that cannot be turned off by a switch or pull chain.
The fuse (or circuit breaker) size should be 15 Amps.
Recommended Grounding Method
For your personal safety, this appliance must be grounded. It is equipped with a power
supply cord that has a 3-pronged grounding plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-pronged wall socket, and grounded in accordance
with the National Electrical Code and local codes and ordinances. If a mating wall socket
is not available, it is the personal responsibility of the customer to have a properly
grounded, 3-prong wall receptacle installed by a qualified electrician.