Quick Start Guide-R01

Quick Start Guide
– 2 –
Verify Device is Powered On
1. Verify the device is powered on by checking the Power LED.
When operating normally, the Power LED should be on green.
Connect Network Cables
1. For the RJ-45 ports, connect Category 5e or better twisted-pair
cable.
2. First install SFP/SFP+ transceivers and then connect fiber optic
cabling to the transceiver ports.
The following transceivers are supported in the SFP+ ports:
10GBASE-SR
1000BASE-SX
3. As connections are made, check the port status LEDs to be sure
the links are valid.
Connect to the Console Port
1. Connect a PC to the serial console port using the included
console cable.
2. Configure the PC’s serial port as follows:
115200 bps
8 characters
No parity
One stop bit
8 data bits
No flow control
3. Log in to the Ubuntu system using the default settings:
Username “root
Passwordaccton
Specifications
4
1
5
1
2
6
Form Factor 1 RU rackmount
Dimensions
(W x D x H):
442 x 298.3 x 43.6 mm (17.4 x 11.74 x 1.72 in.)
Weight 5.24 kg (11.55 lb), with one installed PSU
CPUs CPU Intel® Atom™ Processor C3758 SoC (14nm)
2.2 GHz
Support 8 cores
Memory Sockets: 2x260pin DDR4 SODIMM slots
Type: 2 x 8GB DDR4-2400 ECC DRAM (32GB max)
Local Storage 1 x M.2 SATA 3 SSD, 128GB
I/O Interfaces 1 x USB 3.0 Type A
1 x RJ-45 serial console
Network
Interfaces
4 SFP+ 10GbE ports
8 RJ-45 GbE ports
Expansion Type: Internal Mini PCIe slots x2
Accelerator Advanced Technologies: Intel QuickAssist, VT-x, VT-
d, EPT, AES-NI
Storage Encryption: TPM V2.0
Power Supply
Unit Rating
Input: AC 110V to 240V @ 50/60 Hz
Type: 300 W
System
Cooling
Two active fans in rear, support smart fan speed
control
Temperature Operating: 0 °C to 40 °C (32 °F to 104 °F)
Storage: -40 °C to 70 °C (-40 °F to 158 °F)
Humidity Operating: 5% to 95% (non-condensing)
Storage: 5% to 90% (non-condensing)
Compliances CE
FCC
CB
UL/cUL
RoHS 2.0