RPS900W_IG-R01_1014
Chapter 2
| Installing the RPS
Understanding the SYS and PoE LEDs
– 23 –
4. Check the LEDs on the RPU to ensure that the DC voltages being supplied to the
switch are correct. If not, recheck the power cord connections at the AC supply
source and back panel power input connector. See “Understanding the SYS and
PoE LEDs” on page 23.
Understanding the SYS and PoE LEDs
The RPS includes LED indicators for each DC supply to indicate their status. The LEDs
are located on the right-side of the front panel as shown below and described in the
following table.
Figure 11: SYS and PoE LEDs
Table 2: AC Power Supply Specifications
Item Description
AC Input AC 100-240 V, 50-60 Hz, 12 A @ 100 VAC, 6 A @ 240 VAC
Power Supply 100-240 VAC, 50-60 Hz, auto-sensing
Maximum Power Output 11.3 VDC: 126 W
53.8 VDC: 780 W
SYS Status LED PoE Status LED
1
2
1
2