RPS600WA-38 Manual
LEDs
1-3
1
Table 1-1 Port Status LEDs
LED (1-4) Condition Status
Link Off The port does not have a valid connection to a switch.
On Yellow The port has a valid connection to a switch.
Flashing Yellow There has been an RPS internal power failure.
Activity Off The port is not providing power to the connected switch.
Flashing Green The port has been shut down due to one of the following
conditions:
• The unit has detected an over-current condition.
• One or more of the unit’s fans have failed.
On Green The port is providing power to a connected switch.
Table 1-2 System LEDs
LED Condition Status
Fan On Green The fans are functioning normally.
Flashing Yellow One or more fans are not operating properly.
Off The unit is powered off.
Thermal On Green The temperature of the unit is within an acceptable range.
Flashing Yellow Indicates a high temperature that is approaching an
over-temperature condition.
Off The thermal unit has failed, or the unit is powered off.
Power On Green AC power is being supplied to the RPS.
Off No AC power is being supplied to the RPS.