ES3528MV2 DC_Management Guide-R03

Table Of Contents
C
HAPTER
14
| Basic Administration Protocols
Connectivity Fault Management
– 524 –
PARAMETERS
These parameters are displayed:
Creating a Maintenance Domain
MD Index – Domain index. (Range: 1-65535)
MD Name – Maintenance domain name. (Range: 1-43 alphanumeric
characters)
MD Level – Authorized maintenance level for this domain.
(Range: 0-7)
MIP Creation Type – Specifies the CFM protocol’s creation method for
maintenance intermediate points (MIPs) in this domain:
Default MIPs can be created for any maintenance association
(MA) configured in this domain on any bridge port through which
the MAs VID can pass.
Explicit – MIPs can be created for any MA configured in this domain
only on bridge ports through which the MAs VID can pass, and only
if a maintenance end point (MEP) is created at some lower MA
Level.
None – No MIP can be created for any MA configured in this
domain.
Configuring Detailed Settings for a Maintenance Domain
MD Index – Domain index. (Range: 1-65535)
MEP Archive Hold Time – The time that data from a missing MEP is
retained in the continuity check message (CCM) database before being
purged. (Range: 1-65535 minutes; Default: 100 minutes)
A change to the hold time only applies to entries stored in the database
after this attribute is changed.
MEP Fault Notify Lowest Priority The lowest priority defect that is
allowed to generate a fault alarm. (Range: 1-6, Default: 2)
MEP Fault Notify Alarm Time – The time that one or more defects
must be present before a fault alarm is issued. (Range: 3-10 seconds;
Default: 3 seconds)
MEP Fault Notify Reset Time – The time after a fault alarm has been
issued, and no defect exists, before another fault alarm can be issued.
(Range: 3-10 seconds; Default: 10 seconds)
WEB INTERFACE
To create a maintenance domain:
1. Click Administration, CFM.
2. Select Configure MD from the Step list.