(AS4630-54TE) Quick Start Guide R02

Quick Start Guide
– 3 –
Make Network Connections
(Optional) Make Stack Connections
Note:
Stacking support is dependent on the switch software.
For stacking support information, refer to the NOS software
documentation.
5
1. RJ-45 ports
Connect 100-ohm Category 5, 5e or better twisted-pair cable.
2. SFP+/SFP28 slots
First install SFP+/SFP28 transceivers and then connect fiber optic
cabling to the transceiver ports.
6
1. Connect the top device
Plug one end of a DAC cable in the bottom QSFP28 port of the top
unit.
2. Connect the next device
Plug the other end of the DAC cable into the top QSFP28 port of the
next unit.
3. Repeat
Repeat for each unit in the stack.
4. (Optional) Connect the top and bottom devices
Plug one end of a DAC cable into the bottom QSFP28 port on the
bottom unit and the other end into the top QSFP28 port on the top unit.
5. Reboot
Reboot each switch in the stack to start the stack operations.
Hardware Specifications
Switch Chassis
Size (WxDxH) 438 x 474 x 44 mm (17.24 x 18.66 x 1.73 in)
Weight 6.98 kg (15.39 lb), with two installed PSUs
Temperature Operating: 0° C to 45° C (32° F to 113° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 95% (non-condensing)
Power
Consumption
150 Watts max.
2 x 150 W Power Supplies
AC Input 100-240 Vac, 50-60 Hz, 3-1.5 A
Regulatory Compliances
Emissions EN 55032:2015+AC:2016, Class A
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
FCC Class A
VCCI Class A
BSMI Class A, CNS 13438
Immunity IEC 61000-4-2/3/4/5/6/8/11
EN 55024:2010+A1:2015
EN 55035:2017
Safety UL (UL 62368-1 & CSA C22.2 No. 62368-1)
CB (IEC/EN 60950-1, IEC/EN 62368-1)
BSMI, CNS 14336-1
Taiwan RoHS CNS 15663