Potential conditions which may be listed by the diagnostics include those listed
below. Note that TDR testing can only show Test failed or OK.
Test failed
OK: Correctly terminated pair
Open: Open pair, no link partner
Short: Shorted pair
Impedance mismatch: Terminating impedance is not in the reference
range.
No cable
Not tested
Not Supported: This message is displayed for any Gigabit Ethernet ports
linked up at a speed lower than 1000 Mbps, or for any 10G Ethernet ports.
Unknown – Unknown error
Ports are linked down while running cable diagnostics.
Parameters
These parameters are displayed:
Port – Switch port identifier.
Type – Displays media type. (GE – Gigabit Ethernet, Other – SFP)
Link Status – Shows if the port link is up or down.
Test Result – The results include common cable failures, as well as the status
and approximate distance to a fault, or the approximate cable length if no fault
is found.
To ensure more accurate measurement of the length to a fault, first disable
power-saving mode on the link partner before running cable diagnostics.
For link-down ports, the reported distance to a fault is accurate to within +/- 2
meters. For link-up ports, the accuracy is +/- 10 meters.
Last Updated – Shows the last time this port was tested.
Test – Initiates cable test.