Web Management Guide-R05

Table Of Contents
Chapter 13
| Basic Administration Protocols
Connectivity Fault Management
– 505
Displaying
Fault Notification
Settings
Use the Administration > CFM > Show Information (Show Fault Notification
Generator) page to display configuration settings for the fault notification
generator.
Parameters
These parameters are displayed:
MEP ID
– Maintenance end point identifier.
MD Name
– Maintenance domain name.
MA Name
– Maintenance association name.
Highest Defect
– The highest defect that will generate a fault alarm.
(This is disabled by default.)
Lowest Alarm
– The lowest defect that will generate a fault alarm
14
.
Alarm Time
– The time a defect must exist before a fault alarm is issued
14
.
Reset Time
– The time after a fault alarm has been issued, and no defect exists,
before another fault alarm can be issued
14
.
Web Interface
To show configuration settings for the fault notification generator:
1.
Click Administration, CFM.
2.
Select Show Information from the Step list.
3.
Select Show Fault Notification Generator from the Action list.
Figure 321: Showing Settings for the Fault Notification Generator
14. See “Configuring CFM Maintenance Domains” on page 478.