Web Management Guide-R05

Table Of Contents
Chapter 13
| Basic Administration Protocols
Connectivity Fault Management
– 495
Parameters
These parameters are displayed:
MD Index
– Domain index. (Range: 1-65535)
MA Index
– MA identifier. (Range: 1-2147483647)
Source MEP ID
– The identifier of a source MEP that will send the delay-
measure message. (Range: 1-8191)
Target
MEP ID
– The identifier of a remote MEP that is the target of a delay-
measure message. (Range: 1-8191)
MAC Address
– MAC address of a remote MEP that is the target of a delay-
measure message. This address can be entered in either of the following
formats: xx-xx-xx-xx-xx-xx or xxxxxxxxxxxx
Count
– The number of times to retry sending the message if no response is
received before the specified timeout. (Range: 1-5; Default: 5)
Packet Size
– The size of the delay-measure message. (Range: 64-1518 bytes;
Default: 64 bytes)
Interval
– The transmission delay between delay-measure messages. (Range:
1-5 seconds; Default: 1 second)
Timeout
– The timeout to wait for a response. (Range: 1-5 seconds; Default: 5
seconds)
Web Interface
To transmit delay-measure messages:
1.
Click Administration, CFM.
2.
Select Transmit Delay Measure from the Step list.
3.
Select an entry from MD Index and MA Index.
4.
Specify the source MEP, the target MEP using either its MEP identifier or MAC
address, set the number of times the delay-measure message is to be sent, the
interval, and the timeout.
5.
Click Apply.