EXAMPLE
Console(config)#synce auto-clock-source-selecting revertive-switching
Console(config)#end
Console#show synce
SyncE Status:
Port Status Clock Source
--------- -------- ------------
Eth 1/25 Enabled Yes
Eth 1/26 Disabled No
Eth 1/27 Disabled No
Eth 1/28 Disabled No
SyncE Clock Source Selection Mode: Auto
SyncE Active Clock Source Locked: No
SyncE Clock Source Status:
Port Priority Active Clock Source Clock Status
--------- -------- ------------------- ------------
Eth 1/25 25 Yes Bad
...
synce force-clock-
source-selecting
This command sets the local clock as the active clock source, or sets a port
to be the active clock source.
SYNTAX
synce force-clock-source-selecting [ethernet unit/port]
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 25-28)
DEFAULT SETTING
Disabled
COMMAND MODE
Global Configuration
COMMAND USAGE
If this command is used without specifying a clock source port, and
SyncE has not been enabled on any port, then the local clock is set to
be the active clock source.
If SyncE has been enabled on more than one port, the switch will
choose the clock source port based on the current clock source port
status and priority.
A port can be forced to be the clock source port regardless of the
clock’s signal status.
EXAMPLE
Console(config)#sync ethernet 1/25 clock-source priority 1
Console(config)#