ECS4660-28F_Management Guide-R03

Table Of Contents
C
HAPTER
24
| System Management Commands
System Status
– 907 –
There are two thermal detectors in the switch The first detector is near
the air flow intake vents. The second detector is near the switch ASIC
and CPU.
EXAMPLE
Console#show system
System Description : ECS4660-28F
System OID String : 1.3.6.1.4.1.259.10.1.10
System Information
System Up Time : 0 days, 5 hours, 44 minutes, and 42.28 seconds
System Name :
System Location :
System Contact :
MAC Address (Unit 1) : 00-00-0C-00-00-FD
Web Server : Enabled
Web Server Port : 80
Web Secure Server : Enabled
Web Secure Server Port : 443
Telnet Server : Enabled
Telnet Server Port : 23
Jumbo Frame : Disabled
System Fan:
Force Fan Speed Full : Disabled
Unit 1
Fan 1: Ok Fan 2: Ok Fan 3: Ok
System Temperature:
Unit 1
Temperature 1: 29 degrees Temperature 2: 32 degrees
Main Power Status : Up
Redundant Power Status : Not present
Main Power Type : [AC100~240V to +12V Module]
Redundant Power Type : [None]
Console#
show tech-support This command displays a detailed list of system settings designed to help
technical support resolve configuration or functional problems.
COMMAND MODE
Normal Exec, Privileged Exec
COMMAND USAGE
This command generates a long list of information including detailed
system and interface settings. It is therefore advisable to direct the output
to a file using any suitable output capture function provided with your
terminal emulation program.
EXAMPLE
Console#show tech-support
show system:
System Description : ECS4660-28F
System OID String : 1.3.6.1.4.1.259.10.1.10
System Information
System Up Time: 0 days, 2 hours, 17 minutes, and 6.23 seconds